Southbend STRG-5D, STRG-3D manual Buzzer Does Not Come On When Timer Runs Out, PAGE 26 OF

Models: STRG-3D STRG-5D

1 50
Download 50 pages 48.74 Kb
Page 26
Image 26
Buzzer Does Not Come On When Timer Runs Out

SERVICE

STRATOSTEAM COUNTERTOP STEAMER

Figure 13

Buzzer Does Not Come On When Timer Runs Out

Buzzer does not come on when timer runs out.

DISCONNECT POWER AT CIRCUIT BREAKER

Remove right side panel for access.

Set timer for 5 minutes.

No

Does timer time down?

Yes

 

 

 

Replace timer.

Disconnect buzzer lead wires from the timer.

Check the timer (see page 33).

No

Timer OK?

Yes

Replace timer.

Replace buzzer.

PAGE 26 OF 50

OWNERS MANUAL 1185290

Page 26
Image 26
Southbend STRG-5D, STRG-3D Buzzer Does Not Come On When Timer Runs Out, Disconnect Power At Circuit Breaker, PAGE 26 OF