SERVICE | STRATOSTEAM COUNTERTOP STEAMER |
Figure 11
Steamer Not Heating Up, “Power” Light Is Not Lit
Steamer not heating up, “Power” light not lit.
DISCONNECT POWER AT CIRCUIT BREAKER
Remove right side panel for access.
Reconnect power at circuit breaker.
Turn lever to “ON” position and close door (to actuate door switch).
Check voltage between TB5 and TB6
| Is measured |
| |
No | Yes | ||
voltage 120, 208, 220, or 240 | |||
| volts? |
| |
|
|
DISCONNECT POWER AT CIRCUIT BREAKER
Check continuity between cord and TB5 and TB6
Test operation of power switch. Replace if necessary. If power
switch is OK, replace “Power” light and follow procedure.
| Is continuity |
| |
No | Yes | ||
present? | |||
|
|
Replace Power Cord
No
Check continuity across
Power Switch
Is continuity | Yes | |
present? | ||
|
Replace Power Switch
Replace Power Light
PAGE 24 OF 50 | OWNER’S MANUAL 1185290 |