Southbend STRG-5D Steamer Not Heating Up, “Power” Light Is Not Lit, voltage 120, 208, 220, or

Models: STRG-3D STRG-5D

1 50
Download 50 pages 48.74 Kb
Page 24
Image 24
Steamer Not Heating Up, “Power” Light Is Not Lit

SERVICE

STRATOSTEAM COUNTERTOP STEAMER

Figure 11

Steamer Not Heating Up, “Power” Light Is Not Lit

Steamer not heating up, “Power” light not lit.

DISCONNECT POWER AT CIRCUIT BREAKER

Remove right side panel for access.

Reconnect power at circuit breaker.

Turn lever to “ON” position and close door (to actuate door switch).

Check voltage between TB5 and TB6

 

Is measured

 

No

Yes

voltage 120, 208, 220, or 240

 

volts?

 

 

 

DISCONNECT POWER AT CIRCUIT BREAKER

Check continuity between cord and TB5 and TB6

Test operation of power switch. Replace if necessary. If power

switch is OK, replace “Power” light and follow procedure.

 

Is continuity

 

No

Yes

present?

 

 

Replace Power Cord

No

Check continuity across

Power Switch

Is continuity

Yes

present?

 

Replace Power Switch

Replace Power Light

PAGE 24 OF 50

OWNERS MANUAL 1185290

Page 24
Image 24
Southbend STRG-5D manual Steamer Not Heating Up, “Power” Light Is Not Lit, Disconnect Power At Circuit Breaker, PAGE 24 OF