INSTALLATION | STRATOSTEAM COUNTERTOP STEAMER |
Figure 6
Location of Connections and Vents
STEP 3: DRAIN CONNECTION
The drain outlet is located on the back of the steamer, as shown in Figure 6. The drain connector on the steamer is 1" NPT female.
Position the steamer near, but not on top of, an open floor drain. DO NOT directly plumb the steamer unless you also install an “open funnel” downstream of this connection in the drain system. Make the drain line from the steamer to the air gap above the “open funnel” as short as possible. There should be no horizontal piping between the steamer and the air gap above the open funnel. The open funnel is intended to eliminate any water from entering the steamer because of a blocked drain, and it also prevents any back pressure within the steamer cavity. Any connection that allows the
PAGE 16 OF 50 | OWNER’S MANUAL 1185290 |