Models STRG-3D and STRG-5D
StratoSteam Countertop Steamer
DANGER
SAFETY PRECAUTIONS
FIRE HAZARD FOR YOUR SAFETY
BURN HAZARD
INTRODUCTION
Location of Serial Plates
SPECIFICATIONS
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
HARDNESS 2 GRAINS 35 PPM OR LESS pH 7.0 to
CONNECTION ¼” COMPRESSION, COLD WATER PRESSURE 30 TO 60 PSI
TOTAL DISSOLVED SOLIDS TDS 60 PPM OR LESS
MAXIMUM FILL CAPACITY 0.87 GALELECTRIC CABLE ENTRY HOLE
WATER REQUIREMENTS
ELECTRICAL REQUIREMENTS
GAS PRESSURE REQUIREMENTS
DRAIN REQUIREMENTS
Problem
NOTICE WATER SPECIFICATION
OPERATION
Possible Causes and Solutions
Thermometer
Timer
Power Light
Control Lever
COOKING TIPS
PAGE 9 OF
SUGGESTED COOKING TIMES
CLEANING & MAINTENANCE
DAILY CLEANING AND MAINTENANCE
STAINLESS-STEEL SURFACES
PERIODIC DE-LIMING AS NEEDED
PAGE 12 OF
INSTALLATION
PAGE 13 OF
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
Attach Legs
STEP 2C MOUNTING ON CABINET BASE
Installation on Countertop
STEP 2B ATTACH TO COUNTERTOP
STEP 2D STACKING TWO STEAMERS
Location of Connections and Vents
STEP 3 DRAIN CONNECTION
Water Connection
Water Drain
STEP 4 WATER CONNECTION
TESTING THE GAS SUPPLY PIPING
STEP 5 GAS CONNECTION
Electrical Connection
STEP 9 SHUT-DOWN AND WIPE-CLEAN STEAMER
STEP 7 CHECK THE INSTALLATION
STEP 8 CHECK STEAMER OPERATION
SERVICE
Troubleshooting Flowchart, Procedure, or Wiring Diagram
TROUBLESHOOTING FLOWCHARTS, PROCEDURES, AND WIRING DIAGRAMS
HOW THE STEAMER OPERATES
How the Steamer Operates
PAGE 23 OF
DISCONNECT POWER AT CIRCUIT BREAKER
Steamer Not Heating Up, “Power” Light Is Not Lit
DISCONNECT POWER AT CIRCUIT BREAKER
voltage 120, 208, 220, or
Check for loose or broken wires see wiring diagram
DISCONNECT POWER AT CIRCUIT BREAKER
DISCONNECT POWER AT CIRCUIT BREAKER
Is water level at
DISCONNECT POWER AT CIRCUIT BREAKER
Buzzer Does Not Come On When Timer Runs Out
PAGE 26 OF
Hot Surface Ignitor Glows Red, But Burners Not On
PAGE 27 OF
Hot Surface Ignitor Does Not Glow Red
when operating, should draw
Is there 24V from ignitor
natural gas and at least 11” WC for
Not All Burners Ignite
Is gas pressure at least 4” WC for
propane?
Burner Lights But Goes Out Within a Few Seconds
valve?
Cure
Symptom
Possible Cause
burners do not come on when
Power Switch Check
1. DISCONNECT POWER AT CIRCUIT BREAKER
Timer and Buzzer Check
1. DISCONNECT POWER AT CIRCUIT BREAKER
1. DISCONNECT POWER AT CIRCUIT BREAKER
Door Switch Check
PAGE 34 OF
2. DISCONNECT POWER AT CIRCUIT BREAKER
High-Limit Thermostats Check
Water Solenoid Check
1. DISCONNECT POWER AT CIRCUIT BREAKER
PAGE 36 OF
PAGE 37 OF
Wiring Diagram for 208/220/240 Volt and 115 Volt Models
HIGH LIMIT TSTATS
Parts Diagram
PARTS
Structural Parts
Structural Parts
See parts list on previous page
PAGE 40 OF
Door Assembly Parts
NYLON WASHER, 1/4 X 1/2 X 1/8
PIN, .250 DIA, SS, CAST LATCH STEAMER
Door Switch Parts
PAGE 42 OF
1-17
Control Panel Parts
Not shown on drawing
BURNER BOX, STRATOSTEAM GAS
Burner Assemblies, Thermocouple, and Ignition Module
IR BURNER ASSEMBLY, PROPANE
Quantity of part used may depend on model STRE-3D or SRTE-5D
FITTING, 1/8 NPT X 1/4 CC STRAIGHT 1/4 M X 3/8 CC
Water Train Parts
PAGE 45 OF
See parts list on
Water-Train Parts
previous page
Cabinet Base Parts
PAGE 47 OF
Cabinet-Base Parts
PAGE 48 OF
STRATOSTEAM COUNTERTOP STEAMER
PAGE 49 OF
StratoSteam Countertop Steamer Models STRG-3D and STRG-5D