STRATOSTEAM COUNTERTOP STEAMER

SERVICE

Figure 12

Steamer Not Heating Up Properly or Not Cooking Properly, “Power” Light is Lit

Steamer not heating properly or not cooking properly,

“Power” light is lit.

CheckCheckgasgassupplysupplyvalvevalve. .

Turn off steamer and check that it drains completely. If steamer does not drain, check drain path for obstructions. Turn steamer back on and wait 10 minutes.

 

Is water level at

 

No

Yes

normal level in cavity?

 

 

Check that water-supply pressure is adequate.

DISCONNECT POWER AT CIRCUIT BREAKER

Check door switch (see page 34).

No

Door switch OK?

Yes

 

 

 

Replace door switch.

Reconnect door switch lead wires.

Check water solenoid (see page 36).

No

Water solenoid OK?

Yes

 

 

 

DISCONNECT POWER AT CIRCUIT BREAKER

Check high-limit thermostats (see page 35).

No

High-limit thermostats OK?

Yes

 

 

 

Replace high-limit

thermostats as necessary.

Check gas pressure.

Replace water solenoid.

Check for loose or broken wires (see wiring diagram).

If wiring is OK, remove screen

from strainer and clean or

replace as necessary.

Reassemble, reconnect, and recheck the steamer. If water still does not enter the steamer, examine the water solenoid and inline Y strainer for obstructions or deposits. Clean or replace as necessary.

OWNERS MANUAL 1185290

PAGE 25 OF 50

Page 25
Image 25
Southbend STRG-3D, STRG-5D manual Check that water-supply pressure is adequate