SPECIFICATIONS | STRATOSTEAM COUNTERTOP STEAMER |
ELECTRICAL REQUIREMENTS
One fused electrical connection is required to the terminal board of each steamer. All steamers are shipped per customer order, three phase or single phase. (A kit is available for field conversion to three phase or single phase.) The fused connection must be wired for the required voltage and maximum amperage as listed in the chart below:
Voltage |
| Total Connected Amps |
| ||
Model | Model | ||||
|
| 1 Phase | 3 Phase | 1 Phase | 3 Phase |
120 | V 60 Hz | 0.37 | 0.37 | 0.37 | 0.37 |
|
|
|
|
|
|
208 | V 50/60 Hz | 0.21 | 0.21 | 0.21 | 0.21 |
|
|
|
|
|
|
220 | V 50/60 Hz | 0.20 | 0.20 | 0.20 | 0.20 |
|
|
|
|
|
|
240 | V 60 Hz | 0.18 | 0.18 | 0.18 | 0.18 |
|
|
|
|
|
|
GAS PRESSURE REQUIREMENTS
OPERATING
Natural Gas 4" W.C.
Propane Gas 10" W.C.
INCOMING
Natural Gas 7" W.C. Minimum
Propane Gas 11" W.C.
WATER REQUIREMENTS
To meet warranty requirements, the water supply must be as follows:
Connection | 1/4" compression, cold water |
| |
|
|
Pressure | 30 to 60 PSI |
|
|
Total Dissolved Solids (TDS) | 60 PPM or less |
|
|
Hardness | 2 grains (35 PPM) or less |
pH | 7.0 to 7.5 |
Maximum Fill Capacity | 0.87 gallons |
Typical usage is 0.46 gallons per minute at 45 PSI.
In order to minimize service problems and to meet the warranty requirements, a water treatment system (softener) is recommended when water quality does not meet the limits stated above.
DRAIN REQUIREMENTS
The drain outlet has a 1" NPT female connector. Do NOT directly connect the drain to a plumbing system unless you also install an “open funnel” downstream of this connection (see Figure 7 on page 17). There must be no