‰Terminal Resistor Setup

INSTALLATION 2

‰Terminal Resistor Setup

ON ON

1 2 3 4

The terminal resistor is used for the following cases.

zCase 1 : In case that the control cable length between a camera and a controller is relatively very long (1:1 Connection)

If the communication cable length is very long, the electrical signal will bound in the terminal point. This reflected signal causes distortion of original signal. Accordingly, the camera can be out of control. In this case, the terminal resistor of both sides i.e. the camera and the controller must be set to ‘ON’ state.

zCase 2 : In case that multiple cameras are connected to a controller.

Due to similar reasons with the case 1, the terminal resister of the controller and the last camera must be set to ‘ON’ state. The last camera means the camera farthest in cable length from the controller. Do not turn on the terminal resistor of all the cameras on the same communication cable.

Controller

Terminal Resistor ON

RS-485

#1

#2

#n

Terminal Resistor Terminal Resistor

Terminal Resistor

OFF

OFF

ON

37X Speed Dome Camera