INSTALLATION 2
Communication Protocol Setup
ON
ON
1 2 3 4
zSelect an appropriate Protocol with the DIP switch combination.
|
| Switch Mode |
|
|
|
|
| ||||
| P0 |
|
| P1 |
|
| P2 |
|
| Protocol |
|
|
|
|
|
|
|
|
|
| |||
| (Pin 1) |
|
| (Pin 2) |
|
| (Pin 3) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OFF |
|
| OFF |
| OFF |
| ||||
|
|
|
|
|
|
|
|
| |||
| ON |
|
| OFF |
| OFF |
| ||||
|
|
|
|
|
|
|
|
| |||
| OFF |
|
| ON |
| OFF |
| ||||
|
|
|
|
|
|
|
|
| |||
| ON |
|
| ON |
| OFF |
| ||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| Others |
|
|
| Reserved | |||
|
|
|
|
|
|
|
|
|
|
|
|
zMatch the camera protocol with the camera protocol in the setting of your DVR or controller to control the camera.
zAdjust the DIP switch after turning off the camera. If you changed the camera protocol by changing the DIP S/W, the change will be effective after you reboot the camera.
zThe factory default protocol is
zThe factory default protocol is
37X Speed Dome Camera | 12/50 |