Star Trac Pro STM Treadmill Cnt/Rev, Min Pwm, Max Pwm, Date, No Rail, Stop, KEY Down, Speed CHG

Models: Pro STM Treadmill

1 60
Download 60 pages 45.18 Kb
Page 52
Image 52

 

Lowest

Default

Highest

 

Item

Value

Value

Value

Meaning

 

 

 

 

 

ENTERTAIN-

-

OFF

-

ON=Entertainment enabled.

MENT

 

 

 

OFF=Entertainment disabled.

RAIL STOP

-

OFF

-

ON=Enables hardware stop for European units.

 

 

 

 

OFF=Disables hardware stop for European units.

10 REV

22.0

30.7

74.0

Inches of running belt travel for 10 flywheel revolutions, always measured in

 

 

 

 

inches. Nominal values are:

 

 

 

 

1.6" pulley: 27.5

 

 

 

 

1.7" pulley: 29.1

 

 

 

 

1.8" pulley: 30.7

 

 

 

 

2.1" pulley: 35.8

CNT/REV

31

31

125

Number of counts for each motor shaft revolution. Values are:

 

 

 

 

RPM sensor at flywheel notches: 31

 

 

 

 

RPM sensor at motor shaft optical disk: 125

MIN PWM

2

30

55

Pulse duty cycle to obtain the selected MN SPD. Divide MN PWM by 512 to

 

 

 

 

get % duty cycle.

1/2 MX

25

130

170

Pulse duty cycle to obtain 1/2 maximum speed. Divide 1/2 MX by 512 to get %

 

 

 

 

duty cycle.

MAX PWM

86

230

255

Pulse duty cycle to obtain the selected MX Spd. Divide MX PWM by 512 to get

 

 

 

 

% duty cycle.

ACCEL TIME

25

25

60

Time, in seconds, to reach maxmium speed from 0 mph (0 km/hr).

DECEL TIME

20

20

60

Time, in seconds, to reach 0 mph (0 km/hr) from maximum speed.

DATE

1.00

1.98

12.99

Treadmill manufacture date.

NO RAIL

0

0

255

Number of times Hand Rail Stop switch was down or disconnected on power-

STOP

 

 

 

up since last reset.

KEY DOWN

0

0

255

Number of times key other than 5 or 8 was down on power-up since last reset.

SPEED CHG

0

0

255

Number of times speed changed suddenly more than 2 mph (UNITS=English)

 

 

 

 

or 2 km/hr (UNITS=Metric) since last reset.

ELEV STALL

0

0

255

Number of times elevation failed to change (stalled) since last reset.

ELEV RANGE

0

0

255

Number of times elevation was out of range (not between 0% and 15%) at

 

 

 

 

power-up since last reset.

ELEV LOST

0

0

255

After pressing START and reaching 0% reset, the number of times elevation

 

 

 

 

went beyond 0% to 15%, since last reset.

NO MOTOR

0

0

255

Number of times the motor could not verify a load since last reset.

NO SENSOR

0

0

255

Number of time the sensor was inoperable since las reset.

ELEV ZERO

175

240

242

Representation of voltage to elevation motor to obtain 0% elevation. Multiply

 

 

 

 

ELEV ZERO by 0.019608 to get actual voltage.

ELEV MAX

25

57

170

Representation of voltage to elevation motor to obtain 15% (maximum) eleva-

 

 

 

 

tion (incline). Multiply ELEV MAX by 0.019608 to get actual voltage.

 

 

 

 

120 volt treadmill = 57

 

 

 

 

230 volt treadmill = 80

LAST DECK

0

0

65,535

Number of miles (UNITS=English), or km (UNITS=Metric) since the running

 

 

 

 

deck was last serviced or replaced.

LAST BELT

0

0

65,535

Number of miles (UNITS=English) or km (UNITS=Metric) since the running

 

 

 

 

belt was last replaced.

LAST MOTOR

0

0

65,535

Number of miles (UNITS=English), or km (UNITS=Metric) since the motor

 

 

 

 

brushes were last serviced or replaced.

MASTER PIN

0000

4321

9999

Master Personal Identification Number (PIN) for Personal Trainer.

 

 

 

 

 

50

STAR TRAC PRO S / PRO / PRO ELITE TREADMILL OWNERS MANUAL

Page 52
Image 52
Star Trac Pro STM Treadmill Cnt/Rev, Min Pwm, Max Pwm, Date, No Rail, Stop, KEY Down, Speed CHG, Elev Stall, Elev Range