·Con nec tion of an alarm horn to an ex ter nal source of power
»Be fore con nec tion of an ex ter nal power sup ply switch the equip ment off.
Un plug the mains plug.
Re move the fuses F4 (= blend ing unit) or F5 (= alarm).
S 150 jumper as sign ment
Ju1: 1-2: Mi cro pro ces sor in power save mode, open (stan dard)
Ju2/3: 1-2 + 2-4: Ma te rial sen sor with open col lec tor out put
2-3 + 4-5: Ma te rial sen sor with source driver (stan dard)
Ju4/6: 1-2: Ex ter nal RS422 sup ply
2-3: In ter nal RS422 sup ply (stan dard)
Ju5: 1-2: Set value 0-10 kHz (stan dard),
2-3: Set value 0-10 V, 0-20 mA
Ju7: 1-2: Set value 0-20 mA,
2-3: Set value 0-10 kHz (stan dard) or 0-10 V
Ju10: Equip ment sup ply volt age 115 V
Ju11: Equip ment sup ply volt age 230 V (stan dard)
176-1MS
SDD 1 SGM

Elec tri cal ma nu al 10-9

J15 J16 J9* J10 J11 J12 J13 J14 J17
Ju7
1
Ju2
Ju3
1
1Ju5
1
Ju4
Ju6
1
1
Ju1
F2
F3
Ju10
115V
Ju11230V
F7 F1 F5 F4
J8*
L
PE
N
L'
* from serial number 031.03-0108162090
onwards 5 terminals