UNPACKING A N D MOVING

MODELS 424 A N D 424FS I N S TA L L AT I O N

M O D E L S

E L E C T R I C A L R E Q U I R E M E N T S

UNPACKING A N D MOVING

424 424FS

A 115 V AC, 60 Hz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance, is required.

The power supply cord has a 3-prong ground- ing plug, which must be plugged into a mating 3-prong grounding-type wall receptacle. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Installation Specifications illustration on page 3.

IMPORTANT NOTE: For Models 424 and 424FS, the electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Do not use an extension cord or two- prong adapter. Electrical ground is required on this appliance.

Uncrate the unit, remove its wood base and discard the shipping bolts that hold the wood base to the bottom of the unit. Remove all packing materials and tape.

IMPORTANT NOTE: Do not discard the kickplate, anti-tip bracket and hardware. These items will be needed for the installation.

All roller-assembly wine shelves should be removed to reduce weight and prevent them from rolling. To remove, pull the shelf out to its full extension, gently and evenly lift up on both sides of the front of the shelf and remove. Reverse the procedure to reinstall the shelf.

Use an appliance dolly to move the Wine Storage unit. Position the dolly at the back of the unit to prevent damage to finished surfaces.

Before moving the Wine Storage unit in to position, protect any finished flooring with appropriate materials and secure the door closed.

H O M E A L A R M S Y S T E M

If a home alarm system is to be used, refer to Home Alarm Connections on page 8. In addition to operating power, the installer may also be required to supply a home automation system lead to the unit. This is for a low-voltage, low- current signal similar to door and window sensor signals. Common, normally open and normally closed contact configurations are provided.

Three 1/4" (6) female spade connectors are located in the compressor compartment and are accessible behind the kickplate on Models 424 and 424FS. A minimum of 36" (914) of lead wire should be provided for each contact, exiting the back wall near the electrical outlet.

 

Dimensions in parentheses are in

4

millimeters unless otherwise specified.