General Use

TANDBERG Audio Science microphone elements: Audio Technica AT-861PZ and Crown PZM- 6D

 

Signal levels -

 

Clipping level

 

 

 

Nominal level

 

 

microphone

 

 

 

 

 

 

 

 

inputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input menu level

 

Vpp

 

dBu

 

dBu

 

 

settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.0 dB

 

83.0 mVpp

 

-28.4 dBu

 

-46.4 dBu

 

 

 

 

 

 

 

 

 

 

 

1.5 dB

 

69.8 mVpp

 

-29.9 dBu

 

-47.9 dBu

 

 

 

 

 

 

 

 

 

 

 

3.0 dB

 

58.8 mVpp

 

-31.4 dBu

 

-49.4 dBu

 

 

 

 

 

 

 

 

 

 

 

4.5 dB

 

49.4 mVpp

 

-32.9 dBu

 

-50.9 dBu

 

 

 

 

 

 

 

 

 

 

 

6.0 dB

 

41.6 mVpp

 

-34.4 dBu

 

-52.4 dBu

 

 

 

 

 

 

 

 

 

 

 

7.5 dB

 

35.0 mVpp

 

-35.9 dBu

 

-53.9 dBu

 

 

 

 

 

 

 

 

 

 

 

9.0 dB

 

29.4 mVpp

 

-37.4 dBu

 

-55.4 dBu

 

 

 

 

 

 

 

 

 

 

 

10.5 dB

 

24.8 mVpp

 

-38.9 dBu

 

-56.9 dBu

 

 

 

 

 

 

 

 

 

 

 

12.0 dB

 

20.8 mVpp

 

-40.4 dBu

 

-58.4 dBu

 

 

 

 

 

 

 

 

 

 

 

13.5 dB

 

17.5 mVpp

 

-41.9 dBu

 

-59.9 dBu

 

 

 

 

 

 

 

 

 

 

 

15.0 dB

 

14.8 mVpp

 

-43.4 dBu

 

-61.4 dBu

 

 

 

 

 

 

 

 

 

 

 

16.5 dB

 

12.4 mVpp

 

-44.9 dBu

 

-62.9 dBu

 

 

 

 

 

 

 

 

 

 

 

18.0 dB

 

10.4 mVpp

 

-46.4 dBu

 

-64.4 dBu

 

 

 

 

 

 

 

 

 

 

 

19.5 dB

 

8.8 mVpp

 

-47.9 dBu

 

-65.9 dBu

 

 

 

 

 

 

 

 

 

 

 

21.0 dB

 

7.4 mVpp

 

-49.4 dBu

 

-67.4 dBu

 

 

 

 

 

 

 

 

 

 

 

22.5 dB

 

6.2 mVpp

 

-50.9 dBu

 

-68.9 dBu

 

Table1: Signal Levels - Microphone inputs

175

Page 189
Image 189
TANDBERG 6000 MXP user manual 10.5 dB, 12.0 dB, 13.5 dB, 15.0 dB, 16.5 dB, 18.0 dB, 19.5 dB, 21.0 dB, 22.5 dB