Appendices

Cable Specification RS-530/RS-366

TANDBERG MXP and Classic Endpoints that support External Network

Connector on Tandberg End:

oFemale 26pin High Density DSUB Newark P/N 50F2055 or Equivalent

Connector on RS-530:

oDSUB 25 pin Male

Connector on RS-366:

oDSUB 25 pin Male

Cable length:

o1 meter

Signal Name

Female

Male

Male

Comments

 

26pin

25pin

25pin

 

 

DSUB

DSUB

DSUB

 

 

(Tandberg

RS-530

RS-366

 

 

end)

(DCE end)

Pin

 

 

Pin

Pin

Number

 

 

Number

Number

 

 

Frame Ground

1

1

 

Do not connect shield to FGND

Signal Ground

19

7

 

 

Send Data (A)

11

2

 

Twisted Pair

Send Data (B)

12

14

 

 

Send Timing (A)

17

15

 

Twisted Pair

Send Timing (B)

18

12

 

 

Receive Data (A)

13

3

 

Twisted Pair

Receive Data (B)

14

16

 

 

Receive Timing(A)

15

17

 

Twisted Pair

Receive Timing (B)

16

9

 

 

Terminal Ready(A)

20

20

 

 

Terminal Ready(B)

21

23

 

 

Receiver Ready (A)

22

8

 

Twisted Pair

Receiver Ready (B)

23

10

 

Twisted Pair

LOS A

25

18

 

LOS A Unbalanced

RS366 DPR

2

 

2

 

RS366 ACR

3

 

3

 

RS366 CRQ

4

 

4

 

RS366 PND

5

 

5

 

RS366 DLO

6

 

22

 

RS366 NB1

7

 

14

 

RS366 NB2

8

 

15

 

RS366 NB4

9

 

16

 

RS366 NB8

10

 

17

 

RS366 GND

1

 

7

 

315

Page 329
Image 329
TANDBERG 6000 MXP user manual Signal Name Female Male Comments 26pin 25pin, Tandberg RS-530 RS-366 End DCE end Pin