TANDBERG 6000 MXP user manual Appendix 9 Connecting the System to Switched 56 Network, How to call

Models: 6000 MXP

1 341
Download 341 pages 14.2 Kb
Page 291
Image 291

Appendices

Appendix 9: Connecting the System to Switched 56 Network

Connecting the system to the Switched 56 network

Using Telesync TS-256 SW56/ISDN adapter

Connecting the system to the SW56 network using a Telesync Adapter is described below. There are different Telesync Adapters for different configurations of SW56 networks. The network types tested with the system are SW56 2Wire and 4Wire.

Connecting

Connect the system ISDN1 cable to the BRI S/T interface on the Telesync Adapter. Connect the two SW56 cables from the Telesync adapter Line 1 and Line 2 to the SW56 network.

Configuration of the system

Select network type to National ISDN.

LINE 1 SETUP

NUMBER1:

program with number from the first SW56 line

NUMBER2:

program with number from the second SW56 line

SPID1:

program with number from the first SW56 line

SPID2:

Leave blank

How to call

It is important to use Restrict (56k). Select Restrict (56k) in Call Settings in the Call menu (select the field next to the phone book button in the call menu). A second number field will appear when ISDN is selected for Net within Call Settings and you choose bandwidth 128 kbps. Enter the second number in the call settings menu.