SpecificationsMTG100 & MTG300 MPEG Generator Service Manual 1Ć5Table1Ć2: Functional characteristics (Cont.)
Characteristics Description
Delete packet MTG300 only
Targetpacket Deletesthe selected item from the transport stream. If other items with the same PID value as
the selected item exist in the transport stream and they are contained in one packet, they are
also deleted from the transport stream (except for the PCR).
PCR interval setting MTG300 only
PCR interval 20 ms to 10.000 s (1 ms resolution)
PCR interval jitter adder MTG300 only
TargetPCR Selected one PCR
Reference period 20 ms to 10.000 s (1 ms resolution)
Jitter Pattern sine, rectangle, triangle, pulse, ramp, and random
Jitter Duty 1to (period-1) packet(s) (available for pulse)
Jitter Period 5to 3000 packets
Jitter Amplitude 0 to 5.00 s (10 ms resolution)
PCR value jitter adder MTG300 only
TargetPCR Selected one PCR.
Jitter Pattern sine, rectangle, triangle, pulse, ramp, random, and offset
Jitter Duty 1to (period-1) packet(s) (only available for pulse jitter pattern)
Jitter Period 5to 3000 packets (except for the offset mode)
Jitter Amplitude 0 to 5.00 s (resolution of 37 ns, 27 MHz clock)
TS header change MTG300 only
Number of packets 0 to 65535 packets (on every manual operation)
0 value means that the selected operation is executed infinitely.
Targetof change word
operation
Sync_Byte (8)
Transport_error_indicator(1)
payload_unit_start_indicator(1)
transport_priority (1)
PID (13)
transport_scrambling_control (2)
adaptation_field_control(2)
Targetpacket is all the items or one selected item.
Targetof Lack/Duplicate
operation
continuity_counter (4)
Targetpacket is one selected item.