Performance Verification
MTG100 & MTG300 MPEG Generator Service Manual 4Ć5
This test verifies that transport stream data is output correctly from the ASI OUT
connector on the MPEG generator. The following equipment and MPEG test
signal is required for this test:
Oscilloscope
MPEG test system
75 W BNC cable
75 W to 50 W minimum loss attenuator
test64.trp MPEG test signal
Perform the following procedure to verify that transport stream data is output
correctly from the ASI OUT connector on the MPEG generator:
1. Connect the ASI OUT connector on the MPEG generator to the oscilloscope
CH1 input using a 75 W BNC cable and the 75 W to 50 W minimum loss
attenuator as shown in Figure 4-3.
2. Set the oscilloscope controls as indicated below:
Displayed channel CH1. . . . .
Vertical axis 200 mV/div. . . . . . . . . .
Horizontal axis 5 ns/div. . . . . . .
Horizontal position Center. . . .
Record length 500. . . . . . . .
Acquire mode Sample. . . . . . . .
Acquire sequence RUN/STOP button only. . . . .
Trigger mode Auto. . . . . . . . .
Trigger level 0 V. . . . . . . . .
Trigger source CH1. . . . . . . .
Trigger position 50 %. . . . . . .
Trigger slope Rising Edge. . . . . . . . .
Trigger coupling DC. . . . . .
Display style Dots. . . . . . . . .
Input coupling DC. . . . . . . .
Input impedance 50 W. . . . . .
Measure Amplitude. . . . . . . . . . . . .
3. Open the test64.trp file on the MPEG generator.
a. Select Open TS File... from the FILE pull-down menu.
b. In the resulting Select TS File dialog box, select the test64.trp file, and
then press the OK bezel button.
4. Press the START/STOP button on the MPEG generator to start the signal
output of the test64.trp file.
ASI Output