5.4.5 SETADDR

Syntax

<address>SETADDR:<new_address><CR>

Description

Changes the communications address to a new value.

Data Parameters Sent

new_address is the new address for the monitor; Range for new_address is 1-9.

Response

<address>:<success_flag>#<checksum><CR>

Example

Command:

1SETADDR:2<CR> - Change address from 1 to 2

Response:

1:OK#261<CR> - Change Address Successful 1:FAIL#391<CR> - Change Address Failed

Notes

Note that monitor response is from previous address, but any further commands must be at new address. In the example above, after sending back the OK response, the monitor will no longer respond to commands with address 1.

P/N 03662D Teledyne API Model 460H O3 Monitor Operator Manual - Page 27

Page 27
Image 27