Toshiba A09-01P Function Code Access, Display Explanation cont, Quick Reference Guide - Page

Models: A09-01P

1 31
Download 31 pages 32.73 Kb
Page 22
Image 22
Display Explanation (cont.)

Display Explanation (cont.)

 

 

 

 

19: TIMER

 

 

 

 

 

 

 

Display

 

 

Description

 

 

 

 

 

Clock: Displays the current time

 

 

 

 

(AM or PM).

 

 

 

 

 

 

 

 

 

Displays days of the week (Sunday

 

 

 

 

to Saturday).

 

 

 

 

 

 

 

 

 

Lights when the NIGHT button is

 

 

 

 

pressed and goes out when the

 

 

 

 

button is pressed again.

 

 

 

 

Lights when night time quiet

 

 

 

 

operation is set.

 

 

 

 

 

 

 

 

 

Indicates scheduled operation 1

 

 

 

 

status (including setting time).

 

 

 

 

 

 

 

 

 

Displays the scheduled operation

 

 

 

 

step when the scheduled operation

 

 

 

 

STEP1-5 program is set.

 

 

 

 

Lights during time setting and

 

 

 

 

scheduled operation setting.

 

 

 

 

 

 

 

 

 

 

Quick Reference Guide - Page 22

 

 

 

 

 

 

 

 

 

 

21: OPERATION

 

 

Display

 

 

Description

 

 

 

 

 

Lights while internal pump (P1) or

 

 

 

 

external pump (P2) is driven.

 

 

 

 

Lights during backup operation only by

 

 

 

 

 

 

 

 

the heater.

 

 

 

 

Lights when the unit enters the data set

 

 

 

 

 

 

 

 

mode and goes out when the unit exits

 

 

 

 

the data set mode.

 

 

 

 

Lights when the unit enters the service

 

 

 

 

mode and goes out when the unit exits

 

 

 

 

the service mode.

 

 

 

 

Lights when an error occurs and goes

 

 

 

 

out when the error is cleared.

 

 

 

 

Lights for two seconds when settings are

 

 

 

 

 

 

 

 

completed.

 

 

 

 

Lights for two seconds when settings

 

 

 

 

 

 

 

 

failed.

 

 

 

 

 

 

Function Code Access

Set function codes for various operation modes, input using the remote controller. There are 2 types of settings:-

1)Hydro Unit function code setting.

2)Remote controller function code setting.

Setting procedure for Hydro Unit function code

1. Press the TEST Function Code Access + SET Setting procedure for Hydro Unit function code + SELECT Manual background buttons

for four seconds or more to enter the hydro unit function code setting mode.

2.Set the function code number with the TEMP. buttons Manual background (CODE No.: 01 to 91).

3.Set data (DATA) with the TIME buttons Manual background.

4.Press the SET button Manual background to confirm the settings.

5.The CL button Manual background is enabled only before the SET button is pressed and the function code is changed.

6.Press the TEST button Manual background to finish the settings.

Setting procedure for Remote Controller function code

1.Press the TEST Manual background + CL Manual background + TEMP. ▼ buttons for four seconds or more to enter the remote controller function code setting mode.

2.Set the function code number with the TEMP. buttons Manual background (CODE No.: 01 to 13).

3.Set data (DATA) with the TIME buttons Manual background.

4.Press the SET button Manual background to determine the settings.

5.The CL button Manual background is enabled only before the SET button is

pressed and the function code is changed.

6. Press the TEST button Manual background to end the settings.

Page 22
Image 22
Toshiba A09-01P manual Function Code Access, Display Explanation cont, Setting procedure for Hydro Unit function code