22-29 Using AutoCal and ColorCal

12.Place the color measurement page face-down over the grayscale strip.

Place the page at the upper-left corner of the copier/printer glass. Slide the grayscale strip to the top center of the color measurement page. Make sure the patches on the grayscale strip do not overlap the color patches.

Close the platen glass cover, being careful not to move the grayscale strip and color measurement page.

13.On the Control Panel, press Set.

Status messages display the progress of scanning and calculating measurements.

14.When prompted to Print Comparison Page (Expert Mode only), choose Yes to print a preview of the selected calibration.

Choose from a list of output profiles that use the same calibration set and press Set. This option appears only in Expert Mode calibration.

15.When prompted to apply or overwrite the calibration, choose Yes.

16.Choose Yes to confirm.

Status messages display progress information. When calibration is complete, the Control Panel display returns to the Functions menu.