E6581373

2.2. Diagnostics

2.2.1. Service LED

Service LED indicates the node condition.

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continues to

be OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continues to

be ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Momentarily

OFF then continues to be ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeats ON

and OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeats ON

and OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continues to

be OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time (second)

Power

1

2

 

3

 

4

5

ON

 

 

 

 

LED ON

 

 

 

 

LED OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

Phenomenon

 

 

 

 

 

 

Problem & Solutions

1

 

Although the inverter is turned

Check

the connection between the inverter and the

 

 

on, LED remains OFF.

 

 

 

LONWORKS option unit. If abnormality is not found after

 

 

LED continues to be ON after

2

 

checking, it needs to be repaired.

 

 

the inverter is turned on.

 

 

 

 

 

 

 

 

 

 

LED is ON then OFF when

Internal application program is abnormal.

3

the inverter is turned on, and

 

 

it continues to be ON.

 

 

 

If the same indication appears after resetting the power, it

 

 

 

 

 

needs to be repaired.

4

LED flashes every 0.5 second.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a normal action of the "Unconfigured" device. If the

5

LED flashes every 1 second.

device is not "Unconfigured", Internal application program

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is broken. It needs to be repaired.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the program is in the condition of "Configures"

6

 

LED

 

momentarily

turns

ON

status, LED momentarily turns ON when the inverter is

 

then continues to be OFF.

 

 

 

turned on. Then the LED continues to be OFF for some

 

 

 

 

 

seconds. The node indicates "Configured" status that

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

means the normal condition.

-

 

Flicker of LED

 

 

 

 

 

 

CPU is abnormal. It needs to be repaired.

 

(Approximately 10Hz to 30Hz)

 

 

 

 

 

 

 

-

 

LED turns ON while holding

This is normal action while holding down service switch.

 

down service switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

The phone numbers for a service call are listed on the back cover of the inverter instruction manual or on its catalog.

- 6 -

Page 7
Image 7
Toshiba TOSVERT VF-FS1 Series instruction manual Diagnostics, Service LED, Led