Performance

 

Data

(3, 4Ton)

Table PD-1 — Gross Cooling Capacities (MBH) 3 Ton Single/Three Phase

WSC036A1, A3, A4, AW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AmbientTemperature (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

95

 

 

 

 

 

 

 

105

 

 

 

 

 

 

 

 

115

 

 

 

 

 

Enter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EnteringWet Bulb (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Bulb

 

 

61

 

67

 

73

 

 

61

67

73

 

61

67

73

 

 

61

67

73

 

 

 

 

 

 

 

 

 

 

 

Airflow

(F)

 

MBH SHC

 

MBH

SHC

 

MBH SHC

 

 

MBH SHC

 

MBH SHC

 

MBH

SHC

 

 

MBH SHC

 

MBH SHC

 

MBH

SHC

 

 

MBH SHC

 

MBH SHC

 

MBH SHC

 

 

75

34.7

28.9

39.7

22.6

42.4

15.3

 

31.6

27.3

37.1

21.4

41.0

14.4

28.5

25.6

33.8

19.8

39.0

13.3

 

25.3

24.0

30.2

18.2

36.1

12.0

1080

80

35.4

34.8

39.8

28.1

42.9

21.0

 

 

32.5

32.5

37.2

26.8

41.3

20.0

29.9

29.9

33.9

25.2

39.1

18.9

 

27.4

27.4

30.4

23.6

36.2

17.6

 

85

37.7

37.7

 

40.1

33.5

43.4

26.1

 

35.3

35.3

37.6

32.4

41.5

25.3

32.7

32.7

34.4

30.8

39.3

24.4

 

30.1

30.1

31.0

29.2

36.3

23.1

 

 

 

 

 

90

40.0

40.0

40.7

38.9

43.9

31.0

 

 

38.0

38.0

38.3

38.1

41.9

30.4

35.6

35.6

35.6

35.6

39.5

29.8

 

32.9

32.9

32.9

32.9

36.6

28.6

 

75

35.7

30.8

40.3

23.5

42.7

15.5

 

32.5

29.2

37.9

22.3

41.4

14.6

29.3

27.5

34.6

20.8

39.4

13.6

 

26.2

25.9

30.9

19.1

36.8

12.4

1200

80

36.6

36.6

40.5

29.5

43.3

21.9

 

 

34.1

34.1

38.1

28.5

41.7

20.9

31.4

31.4

34.8

26.9

39.7

19.8

 

 

28.7

28.7

31.2

25.3

36.9

18.5

85

39.3

39.3

40.9

35.4

43.9

26.9

 

37.0

37.0

38.5

34.6

42.0

26.3

34.4

34.4

35.4

33.2

39.8

25.7

 

31.7

31.7

32.0

31.6

37.0

24.6

 

 

 

 

90

41.4

41.4

 

41.6

41.2

 

44.4

32.2

 

39.6

39.6

39.6

39.6

42.5

31.8

 

37.3

37.3

37.3

37.3

40.2

31.6

 

 

34.6

34.6

34.6

34.6

37.3

30.6

 

75

36.6

32.7

40.7

24.5

43.0

15.8

 

33.4

31.0

38.5

23.3

41.7

14.9

30.2

29.4

35.3

21.8

39.8

13.8

 

26.9

26.9

31.5

20.1

37.2

12.7

1320

80

38.1

38.1

41.0

30.7

43.6

22.6

 

35.5

35.5

38.7

30.0

42.1

21.6

 

32.8

32.8

35.6

28.6

40.1

20.6

 

30.0

30.0

31.9

26.9

37.4

19.4

 

85

40.4

40.4

41.5

37.0

 

44.2

29.4

 

38.4

38.4

39.3

36.7

42.6

27.5

 

35.9

35.9

36.4

35.5

40.3

26.9

 

33.0

33.0

33.0

33.0

37.6

26.0

 

 

 

 

 

 

90

42.4

42.4

42.4

42.4

44.8

33.2

 

40.8

40.8

40.8

40.8

42.9

33.1

38.7

38.7

38.7

38.7

40.8

33.2

 

36.1

36.1

36.1

36.1

38.0

32.6

 

75

37.3

34.5

41.0

25.1

43.3

16.0

 

34.2

32.9

38.9

24.3

41.9

15.1

30.8

30.8

35.8

22.8

40.1

14.1

 

27.9

27.9

32.0

21.2

37.6

13.0

1440

80

39.2

39.2

41.4

31.9

 

43.9

23.4

 

36.8

36.8

39.2

31.5

42.4

22.1

34.0

34.0

36.2

30.2

40.4

21.4

 

 

31.1

31.1

32.6

28.6

37.8

20.2

85

41.3

41.3

 

42.0

38.5

44.5

28.2

 

39.5

39.5

40.0

38.6

42.9

28.2

37.1

37.1

37.1

37.1

40.7

28.0

 

34.3

34.3

34.3

34.3

38.0

27.3

 

 

 

 

 

 

 

90

43.1

43.1

43.1

43.1

45.1

34.1

 

41.7

41.7

41.7

41.7

43.3

34.3

39.7

39.7

39.7

39.7

41.3

34.7

 

37.3

37.3

37.3

37.3

38.6

34.4

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.

2.MBH = Total Gross Capacity

3.SHC = Sensible Heat Capacity

Table PD-2 — Gross Cooling Capacities (MBH) 4 Ton Single/Three Phase

 

WSC048A1, A3, A4, AW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AmbientTemperature (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

95

 

 

 

 

 

 

 

 

 

105

 

 

 

 

 

 

 

115

 

 

 

 

 

Enter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EnteringWet Bulb (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Bulb

 

61

 

67

 

73

 

 

61

 

67

 

73

 

 

 

61

 

67

 

73

 

 

61

 

67

73

 

Airflow

(F)

MBH SHC MBH

SHC MBH SHC

MBH SHC MBH SHC MBH SHC

MBH SHC MBH SHC MBH SHC

MBH SHC MBH

SHC

MBH SHC

 

 

75

45.9

38.6

52.2

29.8

55.3

20.0

 

42.3

36.5

49.6

28.8

54.2

19.0

 

 

38.5

34.5

45.8

26.5

52.4

17.8

 

34.7

32.5

41.5

25.0

49.5

16.4

1440

80

47.0

46.5

52.4

37.2

55.9

27.7

 

43.6

43.6

49.8

35.9

54.7

26.7

 

40.5

40.5

45.9

34.0

52.6

25.3

37.3

37.3

41.8

32.0

49.6

23.9

85

50.1

50.1

52.8

44.4

56.6

34.0

 

47.4

47.4

50.2

43.4

55.0

33.4

 

44.3

44.3

46.6

41.6

52.9

32.8

41.1

41.1

42.5

39.6

49.8

31.3

 

 

 

 

 

 

90

52.9

52.9

53.6

51.5

57.2

40.3

 

50.9

50.9

51.3

51.1

55.5

40.2

 

48.1

48.1

48.1

48.1

53.2

39.8

45.0

45.0

45.0

45.0

50.0

38.7

 

75

47.2

41.1

52.9

31.1

55.7

20.3

 

43.5

39.1

50.6

29.8

54.7

19.3

 

 

39.7

37.0

46.9

28.0

52.9

18.2

35.8

35.0

42.6

25.9

50.3

16.9

1600

80

48.7

48.7

53.2

38.9

56.4

28.2

 

45.7

45.7

50.8

38.0

55.2

27.7

 

 

42.5

42.5

47.1

36.2

53.3

26.5

39.2

39.2

42.9

34.2

50.4

25.1

85

51.9

51.9

53.7

46.6

57.1

34.9

 

49.6

49.6

51.4

46.3

55.6

34.6

 

46.5

46.5

47.9

44.7

53.5

34.3

43.2

43.2

44.0

42.7

50.6

33.2

 

 

 

 

90

54.4

54.4

54.7

54.1

57.8

41.6

 

52.7

52.7

52.7

52.7

56.1

41.9

 

 

50.3

50.3

50.3

50.3

54.0

42.0

47.3

47.3

47.3

47.3

51.0

41.2

 

 

75

48.3

43.5

53.3

32.0

56.0

20.6

 

44.6

41.5

51.3

31.1

55.0

19.6

 

40.8

39.5

47.7

29.4

53.4

18.5

36.8

36.8

43.4

27.3

50.9

17.2

 

1760

80

50.4

50.4

53.8

40.4

56.7

28.6

 

47.6

47.6

51.5

40.0

55.7

28.4

 

44.3

44.3

48.1

38.4

53.8

27.5

 

40.9

40.9

43.9

36.4

51.1

26.2

85

53.3

53.3

54.5

48.6

57.5

35.6

 

51.3

51.3

52.3

48.8

56.3

36.1

 

48.4

48.4

49.2

47.7

54.1

35.7

45.1

45.1

45.1

45.1

51.3

35.0

 

 

 

 

90

55.5

55.5

55.5

55.5

58.2

42.8

 

54.1

54.1

54.1

54.1

56.7

43.4

 

52.0

52.0

52.0

52.0

54.7

43.9

49.2

49.2

49.2

49.2

51.8

43.6

 

75

49.3

45.8

53.8

32.9

56.3

20.9

 

45.7

43.9

51.8

32.3

55.3

20.0

 

41.9

41.9

48.5

30.7

53.7

18.9

38.1

38.1

44.1

28.6

51.3

17.6

 

1920

80

51.7

51.7

54.3

41.7

57.0

29.1

 

49.1

49.1

52.2

41.7

56.0

28.9

 

45.9

45.9

48.9

40.5

54.1

28.2

42.4

42.4

44.8

38.5

51.6

27.2

 

85

54.3

54.3

55.1

50.3

57.8

36.4

 

52.6

52.6

53.1

51.1

56.7

37.1

 

 

50.0

50.0

50.0

50.0

54.6

37.0

 

46.8

46.8

46.8

46.8

51.8

36.6

 

 

 

 

 

 

90

56.3

56.3

56.3

56.3

58.5

43.8

 

55.1

55.1

55.1

55.1

57.1

44.7

 

53.2

53.2

53.2

53.2

55.2

45.7

50.7

50.7

50.7

50.7

52.5

45.8

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.

2.MBH = Total Gross Capacity

3.SHC = Sensible Heat Capacity

PKGP-PRC003-EN

17

Page 17
Image 17
Trane PKGP-PRC003-EN manual Performance Data, Mbh Shc Mbh Shc Mbh Shc

PKGP-PRC003-EN specifications

The Trane PKGP-PRC003-EN is a high-performance packaged rooftop unit designed to provide efficient heating, cooling, and ventilation solutions for a wide variety of commercial applications. Its innovative design encompasses advanced technologies aimed at improving energy efficiency and overall operational efficiency.

One of the standout features of the PKGP-PRC003-EN is its highly efficient variable speed compressor. This technology allows the unit to modulate its capacity based on the specific needs of the environment, ensuring optimal comfort levels while reducing energy consumption. Coupled with a robust fan system, the unit can maintain precise temperature control in fluctuating weather conditions, providing reliable comfort year-round.

The unit's advanced controls use a user-friendly interface that simplifies operation and monitoring. These controls can be integrated with building management systems (BMS), allowing for seamless connectivity and enhanced control over the HVAC system. With the capability for remote monitoring, facility managers can track performance metrics and receive alerts for maintenance, ensuring that the unit operates efficiently and minimizes downtime.

In terms of design, the PKGP-PRC003-EN is equipped with durable construction materials that withstand outdoor environments, ensuring a long lifespan with minimal maintenance. The unit’s compact footprint allows it to fit in tight spaces on rooftops, making it an ideal choice for urban environments where space is limited.

Furthermore, the Trane PKGP-PRC003-EN incorporates advanced filtration systems to improve indoor air quality. These filters effectively capture dust, pollen, and other allergens, contributing to a healthier indoor environment. The unit is also designed with sound attenuation features, minimizing operational noise, which is particularly beneficial for installations in noise-sensitive areas.

Overall, the Trane PKGP-PRC003-EN sets a high standard in the realm of rooftop HVAC solutions. Its combination of energy efficiency, smart control capabilities, and robust construction makes it a reliable choice for businesses looking to enhance their indoor climate while being mindful of operational costs. The integration of advanced technologies ensures that it not only meets but exceeds the expectations of modern HVAC performance, all while maintaining user-friendly operation and maintenance.