Performance

Data

Table PD-23— Static Pressure Drops Through Accessories (Inches Water Column)

 

 

 

 

 

 

Economizerwith

 

 

 

 

Electric Heater

 

 

Unit

Standard

Standard

 

 

OA/RADampers2

 

 

 

 

Accessory (KW)3

 

Tons

ModelNo.

CFM

Filters1

Pleated Filters

100%OA

100%RA

 

100%OA

100%RA

 

 

5-6

9-15

17-36

54

 

 

 

 

 

Downflow

 

Horizontal

 

 

 

 

 

 

 

 

960

0.04

0.06

0.05

0.01

0.05

0.00

 

 

.013

.016

.019

3

WSC036A

1200

0.06

0.09

0.07

0.02

0.07

0.01

 

 

.020

.025

.030

 

 

1440

0.08

0.12

0.10

0.03

0.10

0.01

 

 

.029

.036

.043

 

 

1280

0.04

0.06

0.08

0.03

0.08

0.01

 

 

.023

.029

.034

4

WSC048A

1600

0.05

0.09

0.12

0.04

0.12

0.01

 

 

.036

.045

.053

 

 

1920

0.08

0.12

0.17

0.06

0.17

0.02

 

 

.052

.064

.077

 

 

1600

0.05

0.09

0.12

0.04

0.12

0.01

 

 

.036

.045

.053

5

WSC060A

2000

0.09

0.13

0.18

0.07

0.18

0.02

 

 

.056

.070

.083

 

 

2400

0.12

0.18

0.26

0.10

0.26

0.04

 

 

.081

.100

.120

 

 

1920

0.04

0.07

0.10

0.01

0.06

0.02

 

 

0.02

0.011

0.021

6

WSC072A

2400

0.06

0.09

0.11

0.02

0.08

0.02

 

 

0.02

0.020

0.034

 

 

2880

0.09

0.12

0.13

0.04

0.10

0.04

 

 

0.04

0.033

0.052

 

 

2400

0.06

0.09

0.11

0.02

0.08

0.02

 

 

0.02

0.020

0.034

WSC090A

3000

0.10

0.13

0.14

0.05

0.12

0.05

 

 

0.05

0.042

0.063

 

 

3600

0.14

0.18

0.21

0.07

0.25

0.08

 

 

0.08

0.077

0.102

 

 

3200

0.07

0.10

0.17

0.05

0.14

0.05

 

 

0.05

0.028

0.036

0.042

10

WSC120A

4000

0.11

0.15

0.26

0.07

0.30

0.08

 

 

0.08

0.045

0.056

0.070

 

 

4800

0.16

0.20

0.34

0.09

0.35

0.10

 

 

0.10

0.065

0.081

0.106

Notes:

1.Tested with standard filters (3-5 tons 1", 6-10 tons 2”). Difference in pressure drop should be considered with utilizing optional 2” pleated filters.

2.OA = Outside Air and RA = Return Air.

3.Nominal KW ratings at 240, 480, 600 volts.

Table PD-24— Electric Heater Voltage

Correction Factors (Applicable to

Auxiliary Heat Capacity)

Nominal

Distribution

Capacity

Voltage

Voltage

Multiplier

 

 

 

 

208

0.751

240

230

0.918

 

240

1.000

 

440

0.840

480

460

0.918

 

480

1.000

 

540

0.810

600

575

0.918

 

600

1.000

Table PD-25 — Outdoor Sound Power Level - dB (ref. 10 -12Watts)

 

Unit

 

 

 

Octave Center Frequency

 

 

Overall

Tons

Model No.

63.

125

250

500

1000

2000

4000

8000

dBA

3

WSC036A

85

82

80

79

77

73

69

68

82

4,5

WSC048,060A

95

88

84

83

80

77

74

70

85

6

WSC072A

92

95

91

88

84

80

75

68

90

WSC090A

91

95

91

88

84

79

75

68

90

10

WSC120A

94

89

87

85

84

78

75

69

88

Note:

 

 

 

 

 

 

 

 

 

 

Tests follow ARI270-95.

28

PKGP-PRC003-EN

Page 28
Image 28
Trane PKGP-PRC003-EN manual Table PD-25 Outdoor Sound Power Level dB ref -12Watts, WSC072A WSC090A WSC120A

PKGP-PRC003-EN specifications

The Trane PKGP-PRC003-EN is a high-performance packaged rooftop unit designed to provide efficient heating, cooling, and ventilation solutions for a wide variety of commercial applications. Its innovative design encompasses advanced technologies aimed at improving energy efficiency and overall operational efficiency.

One of the standout features of the PKGP-PRC003-EN is its highly efficient variable speed compressor. This technology allows the unit to modulate its capacity based on the specific needs of the environment, ensuring optimal comfort levels while reducing energy consumption. Coupled with a robust fan system, the unit can maintain precise temperature control in fluctuating weather conditions, providing reliable comfort year-round.

The unit's advanced controls use a user-friendly interface that simplifies operation and monitoring. These controls can be integrated with building management systems (BMS), allowing for seamless connectivity and enhanced control over the HVAC system. With the capability for remote monitoring, facility managers can track performance metrics and receive alerts for maintenance, ensuring that the unit operates efficiently and minimizes downtime.

In terms of design, the PKGP-PRC003-EN is equipped with durable construction materials that withstand outdoor environments, ensuring a long lifespan with minimal maintenance. The unit’s compact footprint allows it to fit in tight spaces on rooftops, making it an ideal choice for urban environments where space is limited.

Furthermore, the Trane PKGP-PRC003-EN incorporates advanced filtration systems to improve indoor air quality. These filters effectively capture dust, pollen, and other allergens, contributing to a healthier indoor environment. The unit is also designed with sound attenuation features, minimizing operational noise, which is particularly beneficial for installations in noise-sensitive areas.

Overall, the Trane PKGP-PRC003-EN sets a high standard in the realm of rooftop HVAC solutions. Its combination of energy efficiency, smart control capabilities, and robust construction makes it a reliable choice for businesses looking to enhance their indoor climate while being mindful of operational costs. The integration of advanced technologies ensures that it not only meets but exceeds the expectations of modern HVAC performance, all while maintaining user-friendly operation and maintenance.