TV-IP522P ProView Megapixel Internet Camera

B

I/O Terminal Application

Typically used in association with programming scripts for developing applications for motion detection, event triggering, alarm notification via e-mail, and a variety of external control functions. The 8-pin I/O Terminal Block is located on the rear panel and provides the interface of a photo- coupled switch output and a photo-coupled input.

Connector Pin Assignment

Sign

FUNCTION

SPECIFICATION

 

 

 

12V+

DC12V output(+)

Connect to an IR illuminator or other device in parallel

 

 

connection. The total output current should be under 200mA

12V‐

DC12V output(‐)

 

 

 

 

In1+

Photo‐Relay INPUT (+)

Active High voltage 5~40VDC

 

 

Dropout voltage 0 VDC

In1‐

Photo‐Relay INPUT (‐)

 

 

 

In2+

Photo‐Relay INPUT (+)

Active High voltage 5~40VDC

 

 

 

In2‐

Photo‐Relay INPUT (‐)

Dropout voltage 0 VDC

 

 

 

O/P+

Photo‐Relay Output(common)

Close circuit maximum 120mA(Peak load current)

 

 

Open circuit voltage maximum 350v(Peak AC)

O/P‐

Photo‐Relay Output(Normal Opne)

 

 

 

 

SA/+

RS‐485 (+) or (A)

Compliant to RS‐485

 

 

 

SB/‐

RS‐485 (‐) or (B)

 

 

 

 

Monitoring and Controlling

By entering http requests in your browser’s URL field, you can:

Monitor the status of digital input.

Drive the output switch on or off.

71

Page 72
Image 72