Internal Battery Replacement

See the following diagrams for battery removal and installation procedures.

SU1000XLCD

1a Remove the screw from the left of the front bezel. 1b Remove the front bezel.

1a

1b

2Flip open the white connector holder. Disconnect the

connector that’s inside the white connector holder.

3 Remove the screw that holds the metal bar in place (in front of

 

the battery compartment on the left side). Remove the metal

 

bar from the UPS.

2

3

2-3

4Remove the batteries using the pull tab.

Note: Please memorize the original battery position and orientation to ensure that you install the new batteries correctly.

5 Insert the new battery set into the UPS in the same position as the original set.

6Replace the metal bar. Reinstall the screw on the right side

that holds the metal bar in place.

7

Reconnect the DC connector (red-to-red, black-to-black) and

 

 

flip the white connector holder closed. Close the white

 

 

connector holder.

4

8

Reinstall the front bezel and replace the screw on the left of

 

the bezel to secure it to the cabinet.