Auto - the scanner automatically adjusts the digital decode threshold to match the transmission you are hearing when it receives a strong signal and has a high decode rate.

Manual - lets you manually adjust the digital decode threshold. To manually adjust the P25 level, select Manual.

Default - sets the digital decode threshold to the default value. Use this setting to return to the value that usually provides adequate performance. This is handy is you have manually adjusted the value to a setting that prevents proper decoding.

Note: This setting has no effect on how these systems are received.

Setting the EDACS ID Format (EDACS Systems Only)

Menu

Program System

Select the system

Edit Sys Option EDCS ID Format

EDACS talk group ID's are commonly provided in one of two formats: AFS and Decimal. This setting determines how you enter EDACS ID's and how the scanner displays them.

AFS Format - the scanner uses AFS format for talk group ID's

Decimal Format - the scanner uses decimal format for talkgroup ID's

Notes:

The scanner defaults to AFS (agency, fleet, subfleet) format - the format used in most EDACS systems.

See “EDACS Trunking” on Page 27 for more information about the AFS format.

Programming/Editing Optional Settings

82

Page 84
Image 84