39XDV

NOTE: Refer to Figure 57 for bracket and bend loca- tions.

1.Place the log front right. Hold the log with the pointed end toward the left. Place on top of burner toward the right. Slide the log toward the front until it comes in contact with the bracket at the front of the burner housing behind the burner tube. (Fig. 59) Adjust the log until the pointed end on the left is aligned with the left edge of the bracket. (Fig. 60)

Figure 60

Left Edge

Rear Log Bracket

of Bracket

 

Stop

 

Bracket

 

Front Brackets

FP1607

Fig. 59 Burner brackets and bends.

Log Front Right

LG478

2. Place the log overlay. Hold the overlay with the flat side down and large cut out for the middle flame on the right. Set the overlay on top of the burner toward the left front inside the stop bracket on the left end and the bend on the front left of the burner. (Fig. 61) Rotate the right end of the overlay clockwise

until it makes contact with the back

of the log front right. NOTE: This is very critical as improper positioning of the over-

Figure 61

lay will affect the flameLG479 and the performance of the unit.

(Fig. 61)

Log Overlay