Framing and Finishing

Framing and Finishing

Check fireplace to make sure it is levelled and properly positioned.

To mount the appliance:

1.Choose the location.

2.This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while flange “B” is for 5/8” drywall.

3.Bend the desired flanges out 90° on both sides of the fireplace. Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing. Level the unit and secure it firmly in place.

Flange

Drywall

Flange Location for

Position

Depth

Desired Drywall Depth

A1/2” / 13 mm

B

5/8” / 16 mm

AB

FP1539

Fig. 5 Nailing flanges.

Final Finishing

Noncombustible materials such as brick or tile may be extended over the edges of the face of the fireplace. DO NOT cover any vent or grille panels.

If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the fireplace.

33XDV / 36XDV / 39XDV

Certified To

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Units: GFDN3L1, GFDE3L1, GFDN3J1, GFDI3J1, GFDE3JI, GFDN3K1, GFDE3K1

XDV Direct Vent Gas Fireplace

Gas Specifications

 

 

 

Max.

Min.

 

 

 

Input

Input

 

 

 

Model

Fuel

Gas Control

BTU/h

BTU/h

33XDVRN

Nat.

Millivolt Hi/Lo

21,500

4,400

33XDVRP

Prop.

Millivolt Hi/Lo

21,500

5,425

33XDVEN

Nat.

24 Volt Hi/Lo

21,500

4,400

33XDVEP

Prop.

24 Volt Hi/Lo

21,500

5,425

36XDVRN

Nat.

Millivolt Hi/Lo

27,500

5,150

36XDVRP

Prop.

Millivolt Hi/Lo

27,500

5,500

36XDVRFN

Nat.

Comfort Contrl

27,500

5,810

36XDVRFP

Prop.

Comfort Contrl

27,500

6,225

36XDVEN

Nat.

24 Volt Hi/Lo

27,500

5,150

36XDVEP

Prop.

24 Volt Hi/Lo

27,500

5,500

39XDVRN

Nat.

Millivolt Hi/Lo

30,000

6,700

39XDVRP

Prop.

Millivolt Hi/Lo

30,000

5,800

39XDVEN

Nat

24 Volt Hi/Lo

30,000

6,700

39XDVEP

Prop

24 Volt Hi/Lo

30,000

5,800

Gas Inlet and Manifold Pressures

 

 

Natural

LP (Propane)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

 

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the cur- rent ANSI Z223.1/NFPA 54 and/or local codes hav- ing jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

Gas Line Installation

When purging the gas lines, the front win- dow frame assembly must be removed.

The gas pipeline can be brought in through the rear of the appliance as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the rear right side of the valve as this allows fan installation or removal without disconnecting the gas line.