Vermont Casting 36XDV Rear Wall Installation Twist Lock Pipe, XDV Direct Vent Gas Fireplace, Step

Models: 33XDV 39XDV 36XDV

1 56
Download 56 pages 37.23 Kb
Page 15
Image 15
Rear Wall Installation

Rear Vent Top View

20" (508 mm)

 

DVR584-600

Fig. 21 Rear vent application, no elbows.

20"

20"

(508 mm)

(508 mm)

Max.

Max.

45°

45°

REAR VENT-TOP VIEW

FP836

Fig. 22 Rear vent application, one 45° elbow.

Rear Wall Installation

Twist Lock Pipe

STEP 1

Locate vent opening on the wall. To locate hole center consult with appropriate fireplace dimensions, Page 4. Frame as shown below.

NOTE: When using flex vent, the opening will have to be measured according to the 1/2” (13 mm) rise in 12” (305 mm) vertical run.

Combustible Walls (Fig. 23): Cut a 10³⁄”H x 9³⁄” W (264 x 240 mm) hole through the exterior wall and frame as shown.

Noncombustible Walls (Fig. 23): Hole opening must be 7¹⁄” (190 mm) in diameter.

Zero clearance sleeve is only required for combustible walls.

STEP 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (MAXIMUM 12”/305 mm). Assem- ble sleeve and attach to firestop with #8 sheet metal screws (supplied). (Fig. 24)

STEP 3

Measure the horizontal length requirement for the vent- ing including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 22)

XDV Direct Vent Gas Fireplace

Vent Opening for Combustible Wall

9³⁄

(240mm)

 

 

 

 

Framing

10³⁄

 

Detail

 

 

(264mm)

 

 

 

 

 

 

 

Fireplace Hearth

Opening for Noncombustible Wall

7¹⁄

 

(190 mm)

 

 

VO584-100

Fig. 23 Locate vent opening on wall.

 

Adjustable

Max. Length

Zero Clearance

12” (305mm)

 

Sleeve

 

 

#8 Screws (2)

#8 Screws

 

(2)

#8

 

Screws

 

(2)

Firestop

 

Adjustable Zero Clearance Sleeve

ZCS101

Fig. 24 Adjustable zero clearance sleeve.

 

STEP 4

Install the 4” (102 mm) vent to the appliance collar and secure with three (3) sheet metal screws. Install the 7” (178 mm) vent pipe tot he appliance collar and secure with three (3) sheet metal screws. It is not necessary to seal this connection. If a 45° elbow is being used, attach the elbow to the appliance in the same manner then attach the venting to the elbow.

It is critical there is no downward slope away from the appliance when connecting the vent or elbow.

STEP 5

Guide the venting through the vent hole a you place the appliance in its installed position. Guide the 4” (102 mm) and 7” (178 mm) collar of the vent termination into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appliance flue collars. (Fig. 25) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.

10009383