XDV Direct Vent Gas Fireplace
Conversions must be completed by qualified personnel Fuel Conversion Instructions
To convert the XDV units for use with a different gas fol- low these instructions. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
CAUTION: Logs may be HOT! Allow to cool before proceeding.
1.Open louvre assembly bottom to gain access to valve. Remove window frame assembly. (Refer to “Window Frame Assembly Removal”, Page 24, Fig. 48)
2.Remove logs if previously installed.
Honeywell Valve
1.Remove cap from HI/LO knob. This can be accom- plished by lifting the plastic cap off the screw. (Fig. 73)
2.Remove the screw from center of HI/LO knob with small screwdriver turning counterclockwise. (Fig. 73)
3.Insert conversion screw supplied in conversion kit. Blue for natural gas, red for LP.
4.Tighten screw, replace cap.
N
O
F
OFF | |
P | |
| L |
I | |
TO |
|
D
Cap
Lift Open
HI
LO
HI
LO
Remove |
|
Center Screw | CO100 |
|
FC108
Fig. 75 Replace regulator.
Burner Orifice Conversion 33/36XDV
1. | Remove bracket rear log and front grate. (Fig. 76) |
2. | Remove burner housing assembly and front burner |
Fig. 73 Remove center screw from
NOVA SIT820 Valve
1.Using the TORX T20 bit, remove and discard the three (3) pressure regulator mounting screws (A), pressure regulator tower (B) and the spring and diaphragm assembly (C). (Fig. 74)
A
B
C
| OFF |
N | P |
L | |
| I |
O | TO |
FC107
Fig. 74 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly.
| tube. (Fig. 76) |
3. | Remove burner orifice from manifold assembly using |
| 3/8” wrench. (Fig. 76) |
4. | Install conversion orifices in place of orifices just |
| removed. |
|
|
|
| Rear Burner Orifice: |
|
|
|
|
|
|
| Main Burner | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
| (Refer to Conversion Kit |
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| Assembly | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
| Orifice Chart) |
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Front Burner Orifice: |
| Pilot | |
(Refer to Conversion Kit | Front Burner | ||
Location | |||
Orifice Chart) | Tube | ||
FP1612 | |||
|
|
Fig. 76 Remove manifold assembly.
5.Remove air shutters from burner pan by removing shutter retaining screw then air shutter. (Fig. 77)
6.For 36XDV replace only rear air shutter.
Natural Gas: Rear air shutter, close two sides, top and bottom open.
Front air shutter, fully open.
40 | 10009383 |