Vermont Casting 4080, SDVR, PDV20: 3920, 4075, 3930, 4070 Termination Clearances, D Cc E, 20007066

Models: 3966 4080 3926 3936 3960 3970 4065 3976 4070 3930 4075 PDV20: 3920 SDVR

1 44
Download 44 pages 20.04 Kb
Page 11
Image 11
Termination Clearances

Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

Inside Corner

Outside Corner

Recessed Location

 

 

 

B =

 

A =

 

Combustible

A

Combustible

 

6"(152mm)

 

6"(152mm)

V

Noncombustible

 

 

2"(50mm)

 

Noncombustible

V

2"(50mm)

B

 

Balcony -

 

Balcony -

 

with no side wall

 

with perpendicular side wall

 

G

H

 

 

 

 

 

V

 

V

 

 

Combustible &

J

G =

 

 

 

Noncombustible

 

Combustible &

 

 

 

Noncombustible

H = 24"(610mm)

 

12"(305mm)

 

J = 20"(508mm)

 

 

 

 

 D Manual background D Manual backgroundManual background

CC

E

V

C = Maximum depth of 48" (1219mm) for recessed location.

D = Minimum width for back wall of a recessed location. Combustible 38"(965mm) Noncombustible 24"(610mm)

E = Clearance from corner in recessed location. Combustible 6"(152mm) Noncombustible 2"(50mm)

584-15

Fig. 10 Termination clearances.

20007066

11

Page 11
Image 11
Vermont Casting 4080 Termination Clearances, Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters, D Cc E, 20007066