Vermont Casting 4080, SDVR, PDV20: 3920 Thermostat Connection, Install the Front Plate, 20007066

Models: 3966 4080 3926 3936 3960 3970 4065 3976 4070 3930 4075 PDV20: 3920 SDVR

1 44
Download 44 pages 20.04 Kb
Page 24
Image 24
Thermostat Connection

Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Switch

Existing

Assembly

Holes

 

Screws

ST315

 

Fig. 40 Attach switch assembly to rear shroud.

 

TPTHUse only a thermostat rated for 500 - 750 millivolts.

TPTH

ThermostatThis completes assembly of the PDV20 and SDVR stove.Install the Front PlatePILOTADJManual backgroundManual background

ST228

Thermostat Connection

(Optional) R Models Only

Use only a thermostat rated for 500 - 750 millivolts.

Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation.

Thermostat

 

Wire / Gauge

Maximum Run

18

40 feet

20

25 feet

22

16 feet

1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.

2.Connect the thermostat wires to the valve. (Fig. 41)

This completes assembly of the PDV20 and SDVR stove.

Fig. 41 Attach switch wires to valve.

Install the Front Plate

Grasp the Front Plate and lift it into position, engaging the two steel tabs at the upper corners behind the adjacent bosses in the Side Plates. (Fig. 42) Seat the Front against the Sides so that the tabs at the bottom lip engage with the notches in the edge of the stove base.

When properly installed, the bottom of the Front Plate cannot be pulled away from the sides without also lifting it up.

If you are installing optional Warming Shelves, do so now, according to the instructions supplied with that kit.

Bottom Tabs

 

Engage Notch in Base

ST407

 

Fig. 42 Install Stove Front.

24

20007066

Page 24
Image 24
Vermont Casting 4080 Thermostat Connection, Install the Front Plate, Use only a thermostat rated for 500 - 750 millivolts