Vermont Casting 3926, SDVR Connect the Gas Supply Line, Burner Information, Complete the Assembly

Models: 3966 4080 3926 3936 3960 3970 4065 3976 4070 3930 4075 PDV20: 3920 SDVR

1 44
Download 44 pages 20.04 Kb
Page 23
Image 23
Connect the Gas Supply Line

Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Connect the Gas Supply Line

Check the rating plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The PDV20 and SDVR may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on Page 41.

CAUTION

This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below.

The PDV20 and SDVR Heaters and the individual shutoff valves must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The PDV20 and SDVR Heaters must be isolated from the gas supply piping system by closing the individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.

There must be a gas shutoff between the stove and the supply.

In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 21,000 BTUs at a manifold pressure of 3.5” and mini- mum inlet supply for adjustment of 5.5” w.c.

In order to connect Propane, use a fitting with 3/ 8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 21,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjustment of 11.0” w.c.

In the U.S.: Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority.

In Canada: consult the local authority and CSA-B149.1 installation code.

Connect the gas supply and test for leaks. Use a mild soap and water solution applied with a brush no larger than 1” (25mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

Burner Information

The appliance must only use the gas specified on the rating plate, unless converted using a Vermont Castings Fuel Conversion Kit. Refer to Page 41 for correct Fuel Conversion Kit for your stove model.

Coversion instructions are provided with each kit and beginning on Page 33 of this manual.

THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES.

THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY.

In order to connect Natural Gas, use a fitting with a 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 21,000 BTU’s at a manifold pressure of 3.5” and minimum inlet supply for adjustment of 5.5” w.c.

In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 21,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjustment of 11.0” w.c.

Complete the Assembly

Open the swiveling latches (cams) on the top left and right corners of the glass frame.

Position the glass and frame against the firebox by placing the bottom edge on the brackets on the bottom face of the firebox.

Swing the assembly against the firebox, and close the latches firmly against the pins protruding from the firebox top.

Install ON/OFF Switch (R Models ONLY)

The switch assembly parts are found in the parts bag.

1.Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 40)

2.Run wires down back of stove, under bottom of rear shroud to valve.

3.Attach wires to valve terminals. (Fig. 41)

20007066

23

Page 23
Image 23
Vermont Casting 3926, SDVR, PDV20: 3920 Connect the Gas Supply Line, Burner Information, Complete the Assembly, 20007066