Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters
Fireplace Installation Requirements - PDV20
Transition
Connector
25¹⁄₄" |
|
(641mm) | 24³⁄₈" |
| (619mm) |
| 15³⁄₄" |
| (400mm) |
Transition
Connector
22³⁄₈" | (568mm) | 24³⁄₈" | (619mm) |
18³⁄₄" |
|
|
|
(476mm) |
|
|
|
ST379 | ST380 |
Fig. 36 PDV20 minimum lintel height for flush or forward placement.
Fireplace Installations Using Existing Wood Stove Chimneys
Existing Wood Stove |
|
|
|
Chimney PIpe |
|
|
|
Finished |
|
|
|
Combustible Wall |
|
|
|
|
|
| *6" |
|
|
| (152mm) |
22₈³⁄" | (568mm) | 24₈³⁄" | (619mm) |
18³⁄₄" |
|
|
|
(476mm) |
|
|
|
|
|
| ST713 |
*Transition pipe must be at least 6” (152mm) from any combustible material.
Existing
Vent Pipe
Field
Fabricated Cover
Transition Connector
X
ST715
“X” must be 6” (152mm) from any combustible material unless completely covered by field fabricated sheet metal. If 3” vent pipes are covered by sheet metal, the clearance to combustibles may be 2” (51mm).
Fig. 37 PDV20 installations using existing wood stove chimney pipe.
20007066 | 21 |