5.1 - Continuous Illumination

Scan one of the following codes to enable continuous LED illumination.

Enable Continuous Illumination

Disable Continuous Illumination (Default)

Note: Videk recommends only using this feature with cabled units due to increased power consumption.

5.2 - Set Targeting Zone Tolerances

The targeting zone is the area around the outside of the code that is viewed by the imager. The values of each of the following codes are the pixels extending from the outside of the edge of the symbol being scanned. As the targeting zone becomes smaller the targeting laser must be more centered in the sym- bol being scanned. Conversely, as the targeting area outside the code gets larger there is less precision needed with the targeting laser. There is also a greater chance the imager will have more than one code in the field of view. The symbol in focus, closest to the targeting laser will be decoded.

50 Most Accurate

75

100

125

1502004001600 (Default)

Least Accurate

Save Settings

K11020 VisionSensor™ 2030 User Manual, Rev. E, Software ver. 3.1.1000, August 3, 2007 - 45

 