Pharmacode Settings
The Pharmacode symbology is prone to errant results caused by other objects within the field of view of a Code Reader. Therefore, all possible measures should be taken to minimize errors. Measures include:
•Setting the minimum and maximum number of bars
•Setting the minimum and maximum amount of data
•Restricting the processing region or allowable “footprint” size of code
•Identify the characteristics of the target symbols
Correct decoding depends upon the proper selection of one of these sets of characteristics:
Enable PharmaCode - No Color Bars, Horizontal Orientation and Standard (left to right) Decoding
Enable Pharmacode - Color Bars Expected, Horizontal Orientation and Standard (left to right) Decoding
Enable Pharmacode - No Color Bars, Vertical Orientation and Standard (left to right) Decoding
Enable Pharmacode - Color Bars Expected, Vertical Orientation and Standard (left to right) Decoding
Enable Pharmacode - No Color Bars, Horizontal Orientation and Reverse (right to left) Decoding
| K11020 VisionSensor™ 2030 User Manual, Rev. E, Software ver. 3.1.1000, August 3, 2007 - 66 | |
Save Settings | ||
| ||
|
|