Viking Access Systems Q7 manual Edge Sensor contact sensor Installation, Manual Release

Models: Q7

1 50
Download 50 pages 11.63 Kb
Page 13
Image 13
Edge Sensor (contact sensor) Installation

IMPORTANT SAFETY INFORMATION

!WARNING! Not Following these instructions may cause severe injury or death.

NOTE: This type on installation dOEs NOT reverse the gate all the way back to its limits when the edge sensor is obstructed. This installation is only to protect against entrapment and to comply with UL325.

Secondary Entrapment Protection

Edge Sensor (contact sensor) Installation

Edge Sensors or like must be installed to reduce the risk of entrapment.

Use only Miller Edge 3-sided activation type MGR20 or MGS20 to comply with UL325

One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge.

1.A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.

2.A wireless contact sensor such as one that transmits radio frequency (RF) sig- nals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.

Manual Release

When manual operation is required:

1.Unlock and remove the Top Cover.

2.Lift the Release Handle up.

To resume normal operation:

1.Push the Release Handle down.

2.Run the gate closed to search for the installed Positive Stop. (page 20 step 4)

3.Normal operation will now resume.

VIKING TECHNICAL SUPPORT 1.800.908.0884

1 1

 

 

Page 13
Image 13
Viking Access Systems Q7 Edge Sensor contact sensor Installation, Manual Release, When manual operation is required