TROUBLESHOOTING

LED References

In addition to the LCD Display, the control board LEDs monitor the various circuits of the control board. Use the table below to identify the corresponding “TS Ref#” and refer to page 38-41 for further troubleshooting.

 

 

 

 

Page 41

#

LED

Status

Meaning

TS Ref#(s)

1

“Magnetic

OFF

At Closed Limit and Magnetic Lock Relay state is closed across “COM” &

 

 

Lock Relay”

 

“N.C.”. (pg 34). Gate should be at the Close Limit.

 

 

 

SOLID

Not at Closed Limit and Magnetic Lock Relay state is closed across “COM” &

 

 

 

 

“N.O.”. (pg 34). Gate should not be at the Close Limit

 

2

“Check Motor”

OFF

Normal Condition.

 

 

SOLID

The control board is sending power to the motor but the circuit is open.

3

“Battery Low”

OFF

Normal Condition.

 

 

SOLID

Batteries are low. Check power supply to the operator. (pgs 18-19).

 

 

FLASHING

Batteries critically low. Check power supply to the operator. (pgs 18-19).

4

“POWER”

SOLID

Normal Condition.

 

 

FLASHING

Operator is running on batteries only (pgs 18-19).

 

 

OFF

No power to control board.

5

“Radio”

OFF

Normal Condition.

 

 

SOLID

Control Board is receiving an input from a device connected to the

 

 

 

Radio terminal (pgs 30, 42).

6

“UL”

OFF

Normal Condition.

 

 

SOLID

Control Board is receiving an input from a device connected to the UL

 

 

 

terminal (pgs 12-13, 42).

7

“Re-Open”

OFF

Normal Condition.

 

 

SOLID

Control Board is receiving an input from a device connected to the Re-

 

 

 

Open terminal (pgs 29, 32, 42).

8

“ATG”

OFF

Normal Condition.

 

 

SOLID

Control Board is receiving an input from a device connected to the ATG

 

 

 

terminal (pgs 31, 42).

7, 8

1, 2 1, 2

1, 2

1, 2, 4, 5

9, 10

9, 10

9, 10

9, 10

3 6