Viking Access Systems Q7 manual SYNCHRONIZATION WITH B-12, Barrier Arm B-12Synchronization Option

Models: Q7

1 50
Download 50 pages 11.63 Kb
Page 37
Image 37
SYNCHRONIZATION WITH B-12
Figure C

SYNCHRONIZATION WITH B-12

Barrier Arm (B-12) Synchronization Option

NOTE: The Control Board provides a convenient solution for applications that require synchronized operation with the Viking Barrier Arm Operator model B-12.

This type of application opens and closes in the following pattern:

1.Open Command is provided only to the Viking B-12 Barrier Arm Operator.

2.The Barrier Arm will delay to open until this Gate Operator reaches its Open Limit.

3.The Gate Operator will delay to close until the Barrier Arm reaches its Close Limit.

STEP 1 (Figure A & B)

Connect the Gate Operator to the Viking B-12 Barrier Arm Operator as illustrated.

STEP 3 (Figure B)

On the Gate Operator Control Board, activate Sync Mode by placing a jumper on to the pin headers labeled “SYNC”.

Figure A

1

2

STEP 4 (Figure C & D)

Connect Viking B-12 Barrier Arm Operator to the Gate Operator as illustrated.

STEP 2 (Figure A)

At the B-12 Barrier Arm Operator, connect the primary device that will be used as the OPEN input.

Figure B

3

Figure D

4

VIKING TECHNICAL SUPPORT 1.800.908.0884

3 5

 

 

Page 37
Image 37
Viking Access Systems Q7 manual SYNCHRONIZATION WITH B-12, Barrier Arm B-12Synchronization Option, Figure A & B, Figure B