ACCESSORY CONNECTIONS

Magnetic Lock, Lock Solenoid

NOTE: Viking Access Systems does not provide external gate lock devices. These items can be purchased from your dealer or distributor.

Magnetic Lock

( + )

( + )

Lock Solenoid

( + ) ( + )

Power for the Locks:

Do not use the 24VDC power supplied by the control board. An external power supply, or plug-in transformer, must be used for the magnetic lock or lock solenoid. Plug the transformer into the “120VAC” receptacle provided at the operators Power Box. This will prevent rapid drainage of the battery in the event of power failure.

The control boards “Magnetic Lock” relay is rated for 10A-250VAC.

!TECHNICAL TIP: The Magnetic Lock Relay LED will indicate status of the on-board relay even if a lock is not connected to the control board. Refer to page 36.

3 4

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Page 36
Image 36
Viking Access Systems Q7 manual Magnetic Lock, Lock Solenoid, Magnetic Lock Lock Solenoid, Power for the Locks