Viper VR-6000 owner manual Maintenance, Replacing Refrigerant Filter/Dryer

Models: VR-6000

1 76
Download 76 pages 26.06 Kb
Page 20
Image 20
MAINTENANCE

INSTRUCTIONS MANUAL

MAINTENANCE

REPLACING REFRIGERANT FILTER/DRYER

The VIPER VR-6000 is equipped with two high side refrigerant filters/dryers and a low side refrigerant filter/dryer (see figure 14). In order to maintain high qualityrecycled refrigerant:

The low side refrigerant filter/dryer must be changed when the VR-6000 displays the service alarm [SERV] and the led “REPLACE FILTER” lights up.

NOTE: When recovering new refrigerant as when the machine is first placed in service this alarm will light abnormally early and may be cleared by pressing the “SEL” key while turning on the machine.

The high-pressure refrigerant filters/dryers must be replaced after approximately 30 hours of operation or 150 service jobs.

ATTENTION: Use only Clore Automotive Filters Part No. 315-032-000 (Low) and Part No. 315-035-666 (High).

When changing the high pressure filters it is recommended that you disconnect the liquid hose from the storage tank (close the hose valve and the liquid tank valve first), and recover the refrigerant from the machine with another machine through the liquid hose. Then proceed as described below:

1

2

 

3

Fig.14: Dryer filters