INSTALLATION

VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible , avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the Venting Arrangements chart below for minimum and maximum flue lengths. See chart below for minimum distances from roof. Periodically check that the vent is unrestricted.

Required Parts:

Part #

Description

945G

45o Elbow

946-529

Co-linear DV Vertical

 

Termination Cap

948-305

3" Flex - 35 ft.

270-944

U27 Dura-Vent Adapter

946-563

Co-Axial to Co-Linear Adapter Kit

 

which contains the following:

 

Co-linear Flex Adapter (270-585)

 

Outer Pipe (946-257)

 

Inner Pipe Adapter (946-219)

Alternate Approved Caps

980Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with flashing

Venting Arrangements - Vertical Terminations

with Co-linear Flex System for both

Residential & Manufactured Homes/

Mobile Homes

The shaded area in the diagram shows the allowable vertical terminations. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.

Straight Vertical Terminations

14

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

Page 14
Image 14
Waterford Appliances E65-NG1, E65-LP1 Vertical Termination with CO-LINEAR Flex System, Required Parts, Description