Waterford Appliances E65-LP1 Miniumum Horizontal Termination Installations, Optional Components

Models: E65-LP1 E65-NG1

1 40
Download 40 pages 10.27 Kb
Page 15
Image 15
MINIUMUM HORIZONTAL TERMINATION INSTALLATIONS
1 946-202
1 640-530
1 640-545
1 948-128
1 45o Elbow
1 Adapter

INSTALLATION

MINIUMUM HORIZONTAL TERMINATION INSTALLATIONS

See page 10 for Exterior Vent Termination requirements. The E65 is approved for a minimum horizontal termination with the Regency Riser Vent Kit. See the diagram on page 13 for minimum and maximum pipe lengths.

When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. Determine the minimum clearance to combustibles from the rear of the unit to the wall. It is also important to note the wall thickness. Before cutting the vent hole through the wall ensure that ALL vent and termination clearances (see page 7) will be met.

NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.

You will require the following components with your new Regency Rear Vent Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass

or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.

Note: These are the minimum pieces required. Other parts may be required for your particular installation.

Minimum components for a Horizontal Installa- tion:

640-944 Horizontal Termination Kit which includes:

1 946-201 6-5/8" Dia. x 18" Black Pipe

1 946-207 4" Dia. x 18" Aluminum Vent

Wall Penetration Heat Shield

(Wall Thimble) (2 pcs) Riser Vent Terminal Decorative Wall Trim (Black) Tube Mill-Pac Screws

945G*

946-219

Optional Components:

946-204

45o Elbow - 6-5/8" Black pipe

 

and 4" Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent

 

Terminal

946-208/P

Vent Guard

940

Square Wall Thimble Cover*

981Snorkel Termination (36")*

982Snorkel Termination (14")*

942Wall Penetration Heat Shield*

* Simpson Dura-Vent components

DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the E65 Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown

onm page 17.

Qty. Description

1)1 Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length, Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm) inside diameter

2)1 Flex Liner, compressed aluminium 2 ply liner, 4" (102mm) inside diameter

3)4 spring spacers

4)1 90 deg. Elbow

5)1 Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2 pcs.

6)1 Thimble Cover

7)1 Wall Thimble (2 pcs.)

8)1 Adapter

9)1 AstroCap Termination Cap

10)2 Trim Collars

11)1 tube of Mill-Pac, high temperature sealant

12)12 Screws, #8 x 1/2" Self tapping, Stainless Steel

13)14 Screws, #8 x 1/2" Self tapping, Black

14)4 Screws #8 x 1-1/2" Drill Point, Black

15)4 Screws #8 x 1-1/2" Drill Point, Stainless Steel

16)8 Wood screws #8 x 1"

Required but not included in above Kit: 45o Elbow (Part #: 946-214)

Note:

a)Liner sections should be con- tinuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substi- tuted for any other manufac- turer's products.