Waterford Appliances E65-LP1 Gas Pipe Pressure Testing, Valve Description, Model #261-969

Models: E65-LP1 E65-NG1

1 40
Download 40 pages 10.27 Kb
Page 25
Image 25
GAS PIPE

INSTALLATION

GAS PIPE

PRESSURE TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.

The manifold pressure is controlled by a regu- lator built into the gas control, and should be checked at the pressure test point.

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver.

3)Attach manometer to "IN" and/or "OUT" pres- sure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position. Read manometer.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten

Valve Description

1)Gas cock knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection

5)Main Operator

6)Outlet Pressure Tap (Manifold Pressure)

7)Inlet Pressure Tap (Supply Pressure)

8)Pilot Outlet

9)Main Gas Outlet

10)Flange Securing Screw Holes

11)Alternative TC Connection Point

12)Thermoelectric Unit

13)Additional Valve Mounting Hole

CONVERSION KIT FROM NATURAL GAS TO PROPANE

Model #261-969

for Emerald Gas Stoves and Gas Inserts using SIT 820 NOVA Gas Valve

THIS CONVERSION MUST BE DONE BY A

QUALIFIED GAS

FITTER IF IN DOUBT DO NOT DO THIS

CONVERSION !!

Conversion Kit Contains:

Qty.

Part # Description

1910-018 SIT Conversion Kit-50% Turndown LP

1

910-037

LP Injector (Pilot Orifice)

1

904-641

Burner Orifice #50

1908-175 E63/E65 Decal "Converted to Propane"

1908-528 Red "PROPANE" label

1908-780 Instruction Sheet

1)Shut off the gas supply.

2)Open the valve door and remove the control panel.

3)Open the front door. Open the right side door and there is a cutout in the heat shield through which can be seen a wing nut threaded on to a stud attached to the front door. Loosen this nut by turning it counter- clockwise.

4)Carefully remove the logs, embers and rockwool.

5)Remove burner. See diagram below.

Note: Use a magnetic type screwdriver if possible.

Pilot assembly is now accessible

for steps 6) to 11).

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

25

Page 25
Image 25
Waterford Appliances E65-LP1 Gas Pipe Pressure Testing, Conversion Kit From Natural Gas To Propane, Valve Description