4
Tools Needed:
None
Drums
IMPORTANT: Right and left hand is always determined from inside the building looking out.
NOTE: For door section identification see page 4.
TorqueMaster® counterbalance drum assemblies, which consist of cable drums and drum wraps, are marked right and left hand. Uncoil the counterbalance cables and make sure you place the right hand cable loop on the right hand milford pin and place the left hand cable loop on the left hand milford pin. Check to ensure the cable loop fits tightly over the milford pin. Insert a roller into bottom bracket of the bottom section and insert another roller at #1 end hinge at the top of the bottom section. Repeat for other side.
WARNING
Failure to ensure tight fit of cable loop over milford pin could result in cable coming off the pin and allowing door to fall, possibly resulting in severe or fatal injury.
NOTE: Verify astragal (bottom seal) is aligned with door section. If there is more than 1/2” excess astragal on either side, trim astragal even with door section.
Left Hand |
|
TORQUEMASTER® |
|
counterbalance |
|
Drum Assembly |
|
| #1 End Hinge |
| (hinge tube) |
| BOTTOM |
Counterbalance | SECTION |
cable | Rollers |
BOTTOM |
|
SECTION |
|
MILFORD PIN | Bottom bracket |
| |
| BOTTOM |
| SECTION |
Astragal
|
|
| |
5 | Bottom Section | ||
| |||
|
|
| |
Tools Needed: | Center the bottom section in the door | ||
Level | opening. Level section using wooden shims | ||
under the bottom astragal if necessary. | |||
|
Level
BOTTOM
SECTION
Wooden shims (if necessary)
|
|
|
Please Do Not Return This Product To The Store. Contact your local | 9 | |