Wayne-Dalton 9800 installation instructions Winding Torsion Springs

Models: 9800

1 26
Download 26 pages 11.64 Kb
Page 19
Image 19
Winding Torsion Spring(s)

18

Winding Torsion Spring(s)

 

 

 

 

 

 

 

Tools Needed:

Position a ladder slightly to the side of spring

 

 

 

so that the winding cone is easily accessible,

 

 

 

Step Ladder

 

 

 

yet your body is not in direct line with the

 

 

 

3/8” Wrench

winding bars. Check the label attached to the

 

 

 

spring warning tag for the required number of

 

 

 

Approved Winding

 

 

 

complete turns to balance your door.

 

 

 

Bars

9’0” Door Height = Approx 9-5/8 Turns

 

 

 

 

10’0” Door Height = Approx 10-1/2 Turns

 

 

 

 

CAUTION: Use winding bars of

 

 

 

 

correct diameter to wind springs.

 

 

 

 

Do not use screwdrivers or other

 

 

 

 

items to wind springs.

 

 

 

 

WARNING

 

 

 

 

Failure to use only approved

 

 

 

 

steel winding bars of

 

 

 

 

correct diameter can result

 

Spring

INSTALLATION

 

in severe or fatal injury.

 

 

 

WARNING

 

 

 

To avoid possible severe or

 

Winding

 

fatal injury, if you are

 

 

 

cone

 

Torsion

 

 

inexperienced in winding

 

 

 

tube

 

 

 

torsion springs, have springs

 

 

 

 

wound by a trained door

 

 

Approved

 

systems service technician,

 

 

 

 

 

Winding bars

 

using proper tools and

 

 

 

 

 

 

 

instructions.

 

 

 

 

WARNING

 

 

 

 

Prior to winding or making

 

 

 

 

adjustments to the springs, ensure

 

 

 

 

you’re winding in the proper

 

 

 

 

direction as stated in the

 

 

 

 

Installation Instructions.

 

 

 

 

Otherwise the spring fittings may

 

 

 

 

release from spring if not wound

Set screws

 

 

 

in the proper direction and could

 

 

 

 

result in severe or fatal injury.

 

 

 

 

Alternately inserting the steel winding bars

 

 

 

 

into the holes of the spring’s winding cone,

 

 

 

 

rotate the winding cone upward toward

 

 

 

 

ceiling, 1/4 turn at a time, until the required

 

 

 

 

number of complete turns for your door height

 

 

Spring

 

is achieved. As the last 1/8 to 1/4 turn is

 

 

 

 

achieved, securely hold winding bar while

 

 

 

 

tightening both set screws in winding cone to

 

 

 

 

14-15 ft. lbs. of torque (Once set screws

 

 

 

 

contact the tube, tighten screws one full turn).

 

 

 

 

Carefully remove winding bar from winding

 

Winding

 

 

cone. Proceed to wind the second spring in

Torsion

 

 

the same manner. While holding the door

cone

Approved

 

down, to prevent it from rising unexpectedly, in

tube

 

Winding bars

 

 

 

 

the event the spring(s) were overwound,

 

 

 

 

carefully remove vice grips from the torsion

 

 

 

 

tube and the vice clamps from the vertical

 

 

 

 

tracks.

 

 

 

 

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer.

19

To find your Wayne-Dalton dealer; refer to your local yellow pages / business listings or go to Find a dealer area online at www.wayne-dalton.com

Page 19
Image 19
Wayne-Dalton 9800 installation instructions Winding Torsion Springs