Westell Technologies IVX S-Class manual Function 551 Station delivery options

Models: IVX S-Class

1 41
Download 41 pages 10.33 Kb
Page 28
Image 28

Function 5: Voice mail programming

IVX S-Class Administrator’s Manual

Function 551: Station delivery options

Programming of the station options, as shown below, can be performed by the Administrator. In addition, the user can change his phone number and pager number (but not phone or pager delay time). The phone number’s maximum length is 24 digits.

 

1.

2.

3.

4.

5.

6.

 

Number

Delay

Attempts

Interval

Quiet on

Quiet off

1. Phone

2145556789

30

6

60

10:30PM

7:15AM

 

 

 

 

 

 

 

2. Pager

2145551234

0

10

30

 

 

To program, enter the station/extension number and choose 1 for phone number or 2 for pager number. Then, enter:

1.Phone/pager number — The number to be dialed (without the CO line group [9, 8 or 7]).

2.Delay — How many minutes the system is to wait before dialing the phone or pager number. This allows the user to pick up a message if he is in the office.

Range: 0–500.Default: 0.

3.Attempts — How many times the system will call/page. Range: 0–99. (0 turns off delivery.) Default: 3.

4.Interval — How many minutes should elapse between attempts. Range: 1–1440. Default: 30.

5.Quiet period on — When the quiet period should begin. Default: (None.)

6.Quiet period off — When the quiet period should end. Default: (None.)

Notes: For the Quiet period on or Quiet period off parameters, a value in either of 0:00 is invalid and will cause notification not to work.

To insert a special code, press the right scroll key () to select the desired special code:

#,  , F or P (see below). Press # to confirm the inserted character and continue. Press # # to complete the entry.

Use the down arrow key () to backspace.

Once the number is saved you can use the scroll keys to move back and forth to view the number. To edit the number, you must delete it and enter the correct number.

Code

What it produces

## DTMF tone   DTMF tone

F Flash hook

P Two-second pause

Function 552: Delivery/paging parameters

The sequence of programming is as follows:

1.CO line access — Enter the CO line group (9, 8 or 7) that is to be accessed for delivery. Default: 9.

2.Pager dialing pause — When paging, IVX S-Class will send the mailbox number to be shown in the pager’s display. To allow time for the paging service to answer, enter the pause, in seconds, to occur between when IVX S-Class dials the pager number and when it then dials the mailbox number.

Range: 0–20.Default: 6.

D.4

Page 28
Image 28
Westell Technologies IVX S-Class manual Function 551 Station delivery options, Function 552 Delivery/paging parameters