TESTING AN OVEN DOOR LATCH
Gas ranges that have a
Solenoid
Door Latch
Switches (N.O.)
Figure
To test the solenoid windings, perform the following steps:
1.Turn off the gas and electrical power to the range.
2.Set the ohmmeter to the R x 1 position.
3.Remove the wire from either solenoid terminal (see Figure
4.Touch the ohmmeter leads to the terminals of the solenoid. You should obtain a reading of between 40 Ω and 70 Ω.
If the reading is not within the range shown, the solenoid may be considered defective and should be replaced.