Refer to Figure 3-33 for the following sequence.

SEALED BURNER

When a main burner control knob q is turned to the “lite” position, the gas valve r opens, and gas flows through the pressure regulator s into the manifold t through the open valve. As gas passes through the valve and its orifice, it is directed into the venturi u, where it mixes with primary air to create the proper mixture necessary for combustion.

At the same time, line voltage is applied through the ignitor switch v, to the ignitor spark mod- ule w, which produces high-voltage pulses to all of the spark ignitors x. The pulses cause a spark y to occur between the spark ignitor electrode, and the grounded burner cap z. The gas and air mixture at the burner head is ignited by the spark, and a flame is produced at each of the top burner ports.

IGNITOR

SPARK

MODULE

7

HIGH VOLTAGE

 

PULSES

BURNER CAP

PRESSURE

REGULATOR

3

FLOW GAS

10

120 VAC

LINE VOLTAGE

TO SPARK

IGNITOR

IGNITOR SWITCH

 

 

 

GAS

4

6

 

FLOW

2

 

GAS

5

 

 

MANIFOLD

 

GAS VALVE

 

9

SPARK

SPARK IGNITOR

8

BURNER

BURNER FLAME

GAS INLET

AIR SHUTTER VENTURI

OFF

LITE

Figure 3-33

1

BURNER

CONTROL

KNOB

Page 3-24

Page 42
Image 42
Whirlpool 4322452 manual Sealed Burner, Flow