NATURAL AND L.P. GAS CONVERSION

GENERAL

Ranges must be adjusted when going from one type of fuel to another due to the characteristics of the gases. This means that, for efficient combustion, air must be mixed with the gas. The amount of air to be mixed with the amount of gas is called the air-to-gas ratio. The combustion ratio is different between natural and L.P. gas. L.P. gas requires much more air (24:1) to be mixed with it than natural gas (10:1).

Also, there are differences in caloric values between the gasses. When a cubic foot of L.P. gas is burned, it produces much more heat than the same volume of natural gas. This is why the burner orifices must be changed to restrict the gas flow when converting to L.P. use. In other words, the range uses less fuel and more air with L.P. gas to create the same amount of heat with natural gas.

L.P. gas is also distributed and used at higher pressure (11" WCP) than natural gas (4" WCP). This is why the pressure regulator must be converted when changing from natural gas to L.P. operation (refer to the following chart).

NATURAL

PROPANE

BUTANE

CHARACTERISTICS

Colorless, Odorless, Non-Toxic, Gaseous

(Oxidizer Added)

B.T.U./Cu. Ft.

900 to 1100

2500

3010

 

 

 

 

Combustion Ratio Cu.

10

24

31

Ft. Air/Cu. Ft. Gas

 

 

 

 

 

 

 

Operating Pressures:

 

 

 

Manual

8.25 PSI

Not Applicable

Not Applicable

Service

5" - 14" WCP

11" - 15" WCP

11" - 15" WCP

Range

4" WCP

10" WCP

10" WCP

 

 

 

 

GAS CHARACTERISTICS

Change Regulator Orifices & Air Shutters Due To Differences In Gasses

 

 

COOKTOP

OVEN

 

AIR

RANGE TYPE

REGULATOR

BURNER

THERMOSTAT

BURNERS

ADJUST

 

 

SPUDS

 

 

 

 

 

 

 

 

 

 

 

 

NON SELF-CLEAN

X

X

1

X

X

 

 

 

 

 

 

SELF-CLEAN

X

X

2

 

X

 

 

 

 

 

 

COOKTOPS WITH

 

 

 

 

 

CONVENTIONAL

X

X

 

 

X

BURNERS

 

 

 

 

 

 

 

 

 

 

 

COOKTOPS WITH

 

 

 

 

 

SEALED

X

X

 

 

 

BURNERS

 

 

 

 

 

 

 

 

 

 

 