Adjusting and replacing sealing strips

ÎPress pedal which raises bulk waste flap and keep pressed.

ÎDrive machine backwards.

The sweeping track should have an even rectangular shape which is between 2.0 and 2.8 in (50 and 70 mm) wide.

Note

The side brush floating mounting of the roll- er brush adjusts the sweeping track as the bristles wear down. The roller brush must be replaced if it becomes too worn.

Adjusting and replacing sealing strips

ÎPark the sweeper on an even surface.

ÎSet programme switch to step 1 (driv- ing). Roller brush is raised.

ÎTurn main key to "0" and remove it.

ÎPress emergency-stop button.

ÎSecure the machine with wheel chock(s) to prevent it from rolling away.

ÎRaise slightly the waste containers on both sides and pull them out.

ÎOpen the fastening screws of the side panels on both sides.

ÎRemove side panels.

„Front sealing flap

ÎLoosen retaining nuts for the front seal- ing strip (1) slightly (to replace, un- screw).

ÎScrew on new sealing strip without fully tightening the nuts.

ÎAdjust side skirt.

ÎSet the distance between the sealing strip and the floor so that the bottom edge trails behind at a distance of be- tween 0.4-0.6 in (10-15 mm).

ÎTighten nuts.

„Rubber strip

Î If worn, replace.

Î Unscrew retaining nuts for the rubber strip (2).

Î Screw on new rubber strip.

„Rear flap

ÎSet the distance between the sealing strip and the floor so that the bottom edge trails behind at a distance of be- tween 0.2 and 0.4 in (5 and 10 mm).

ÎIf worn, replace.

ÎUnscrew retaining nuts for rear sealing strip (3).

ÎScrew on new sealing strip.

„Side skirts

ÎSlightly loosen retaining nuts for the side sealing strip (to replace, unscrew).

ÎScrew on new sealing strip without fully tightening the nuts.

ÎTo set the floor clearance, insert a sheet with a thickness of between 0.04 and 0.12 in (1 and 3 mm) under the sealing strip.

ÎAdjust side skirt.

ÎTighten nuts.

ÎScrew on side panels.

ÎPush in the waste containers on both the sides and lock them.

Replacing dust filter

￿Danger

Empty waste container before replacing dust filter. Wear a dust mask when working around the dust filter. Observe safety regu- lations on the handling of fine particulate material.

ÎTurn main key to "0" and remove it.

ÎPress emergency-stop button.

ÎOpen the device hood.

ÎLoosen the fastening screws.

ÎPress the filter holder upwards and re- move it.

ÎRemove the lamella filter.

ÎInsert new filter.

ÎMake sure driver engages with holes on drive side.

ÎInsert the filter holder and press down- wards.

ÎTighten the fastening screws.

Note

Make sure when installing the new filter that the fins are not damaged.

Replacing filter case seal

ÎLift filter case seal out of groove in the cover.

ÎInsert new seal.

Checking drive belt

ÎTurn main key to "0" and remove it.

ÎPress emergency-stop button.

ÎOpen the device hood.

ÎCheck tension of circular belt of the side-brush; also check for wear or dam- age.

ÎCheck tension, wear and damages on the V-belt of the sweep roller drive.

ÎCheck tension, wear and damages on the V-belt of the sweep roller drive.

ÎTighten the V-belt at the screw if neces- sary.